Skip to main content
Siemens 5SU1354-1RC16 — Residual Current Breakers (RCCB/RCBO)

Siemens 5SU1354-1RC16 SENTRON RCBO, 16A C-curve 30mA 10kA

MPN5SU1354-1RC16

Siemens SENTRON RCBO, 5SU1354-1RC16, 16A, 2-pole 1P+N, C characteristic, 30 mA Type AC, 10 kA (EN 60898) / 20 kA (IEC 60947-2).

Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & sourcing agent· Listing updated Sep 2026

Specifications

5SU1354-1RC16 — Electrical Ratings
ParameterValue
Number of poles2
Overvoltage categoryIII
5SU1354-1RC16 — Identification
ParameterValue
Product designationRCBO
5SU1354-1RC16 — Mechanical
ParameterValue
Mounting positionany
Width in modular units2
Maximum75 °C
Minimum-40 °C
Width36 mm
Height90 mm
Depth70 mm
Installation depth70 mm
5SU1354-1RC16 — Environmental
ParameterValue
IP degree of protectionIP20, if the distribution board is installed, with connected conductors
5SU1354-1RC16 — Electrical
ParameterValue
Tripping Characteristic ClassC

Product details

The Siemens SENTRON 5SU1354-1RC16 is a 2-module, 2-pole (1P+N) RCBO combining a 16 A overcurrent trip with a 30 mA Type AC residual-current device in a single DIN-rail unit. Supply can enter from either top or bottom, and the unit mounts in any position — no derating for upside-down installation on a crowded DIN rail. The IP20 rating applies once the distribution board is closed and conductors are connected, which is standard for enclosed panel gear.

Panel fit and environmental range

Width is 36 mm (2 modular width units), depth 70 mm, height 90 mm — identical footprint to the standard SENTRON MCB range. The insulation voltage (Ui) is rated at 264 V, surge voltage resistance at 4 kV, and the supply frequency is 50 Hz.

Frequently asked questions

Where can I buy the 5SU1354-1RC16 and get a price?

We source and quote it to order against an RFQ. Availability and current pricing are confirmed at quote time through our independent distribution network. Submit an RFQ for a firm quote with lead time.

What is the difference between 5SU1354-1RC16 and the 5SL6550-7BB MCB?

The 5SU1354-1RC16 is an RCBO (overcurrent + residual current in one unit), while the 5SL6550-7BB is a plain MCB with no ground-fault protection. The RCBO adds the 30 mA Type AC RCD function, so it replaces both a breaker and a separate RCCB in the panel. The MCB is rated 50 A; the RCBO is 16 A. Both share the same 36 mm width, 90 mm height, and DIN-rail mounting, so they fit the same panel slots.

What compliance documentation does Siemens provide for this RCBO?

The 5SU1354-1RC16 carries ratings per EN 60898 (10 kA) and IEC 60947-2 (20 kA), which are the governing standards for MCBs and RCBOs in residential and industrial installations. Standard Siemens documentation includes the declaration of conformity to the Low Voltage Directive, CE marking, and RoHS compliance. Specific certificates (UL, CSA, UKCA, EAC) are not listed in the base spec set — confirm with the order if a particular marine or national approval is required.

MPN
5SU1354-1RC16