Siemens SENTRON 5SU1354-3KK06, RCBO, 1P+N, 6 A rated, Type F residual current 30 mA, tripping characteristic B, 10 kA breaking capacity per EN 60898, 2 MW.

$67.04Ref. price · indicative, final on quote
Sourced new & surplus through independent channelsAuthenticity-screened · ESD-safe packingListing updated Aug 2026

Specifications

5SU1354-3KK06 — Electrical Ratings
ParameterValue
Number of poles2
Overvoltage categoryIII
5SU1354-3KK06 — Identification
ParameterValue
Product designationRCBO
Product design / constructionSuper resistant K
5SU1354-3KK06 — Mechanical
ParameterValue
Mounting positionany
Width in modular units2
Maximum75 °C
Minimum-40 °C
Width36 mm
Height90 mm
Depth77 mm
Installation depth70 mm
5SU1354-3KK06 — Environmental
ParameterValue
IP degree of protectionIP20, if the distribution board is installed, with connected conductors
5SU1354-3KK06 — Electrical
ParameterValue
Tripping Characteristic ClassB

Product details

The Siemens 5SU1354-3KK06 is a SENTRON RCBO combining overcurrent protection (characteristic B, 6 A rated) with residual current detection (Type F, 30 mA trip threshold) in a single 2-module-wide (36 mm) package for 1P+N circuits. Type F residual current detection handles sinusoidal AC faults, pulsating DC faults, and composite faults up to 1 kHz — the standard for single-phase inverter-fed loads like washing machines, heat pumps, and LED drivers where Type A may nuisance-trip on high-frequency leakage.

Temperature derating — the real continuous current ceiling

The mounting position is unrestricted, but the derating curve assumes free convection — stacking in a sealed enclosure without ventilation shifts the effective ambient upward.

Panel fit — 2 MW, 36 mm, any position

IP20 with the distribution board installed and conductors connected — the RCBO itself is not sealed against washdown; it lives inside a cabinet.

Lifecycle and sourcing — active production, quoted to order

No stock-holding claim — each order is quoted to the buyer's required volume.