Siemens 5SU1354-3KK40 SENTRON RCBO, 2-pole 40A Type F, 10kA

MPN5SU1354-3KK40
Active

Siemens SENTRON 5SU1354-3KK40 RCBO, 2-pole 1P+N, 40 A, Type F residual current, B-curve, 10 kA (EN 60898) / 15 kA (IEC 60947-2), 2 MW, IP20.

StockContact for availability
MOQ1 pcs
Sourced new & surplus through independent channelsListing updated Jul 2026

Specifications

Electrical Ratings

5SU1354-3KK40 — Electrical Ratings
ParameterValue
Number of poles2
Overvoltage categoryIII

Identification

5SU1354-3KK40 — Identification
ParameterValue
Product designationRCBO
Product design / constructionSuper resistant K

Mechanical

5SU1354-3KK40 — Mechanical
ParameterValue
Mounting positionany
Width in modular units2
Maximum75 °C
Minimum-40 °C
Width36 mm
Height90 mm
Depth77 mm
Installation depth70 mm

Environmental

5SU1354-3KK40 — Environmental
ParameterValue
IP degree of protectionIP20, if the distribution board is installed, with connected conductors

Electrical

5SU1354-3KK40 — Electrical
ParameterValue
Tripping Characteristic ClassB

Product details

What it is and what it does

The Siemens 5SU1354-3KK40 is a SENTRON RCBO — a combined residual-current circuit breaker and overcurrent protection device in a single 2-module-width (36 mm) package. It protects a 1P+N circuit at 40 A rated current with a B tripping characteristic, and its Type F residual-current detection handles mixed-frequency waveforms from variable-speed drives and other non-sinusoidal loads. The interrupting capacity is 10 kA per EN 60898 and 15 kA per IEC 60947-2, giving it solid fault-clearing headroom for most commercial and light-industrial distribution boards.

What the ratings mean for fit

The 40 A rating holds at 30 °C ambient; at 40 °C it derates to 37.6 A, and at 50 °C to 34.8 A — so if the panel runs hot, size up or verify the actual load stays under the derated curve. The B-curve trips between 3 and 5 times rated current, which is standard for resistive and general-purpose loads; it's not suited for high-inrush motor circuits (use a C or D curve for that). Type F residual current detection covers sinusoidal AC, pulsating DC, and mixed-frequency faults up to 1 kHz — exactly what you get from a VFD-fed load or a washing machine inverter. The 10/15 kA SCCR means it safely interrupts faults up to that level without welding contacts or cascading upstream; that's enough for a typical sub-distribution board fed by a 100–200 A transformer.

Mounting and integration

Snaps onto standard 35 mm DIN rail, occupies 2 modular units (36 mm wide). The supply can enter from either top or bottom — no forced orientation. Installation depth is 70 mm behind the panel face. Rated IP20 once installed in a distribution board with connected conductors, so it's intended for enclosed panels, not exposed washdown areas. Mounting position is any orientation. Halogen-free and silicon-free construction matters for clean-room or high-reliability environments where outgassing can't be tolerated.

Frequently asked questions

Where can I buy 5SU1354-3KK40 and how do I get a price?

This part is sourced and quoted to order against an RFQ through independent distribution. Submit a request for quote; availability and current pricing are confirmed at quote time.

What is the difference between 5SU1354-3KK40 and 5SL6550-7BB?

The 5SL6550-7BB is a different class of device — a miniature circuit breaker (MCB) without residual-current protection. The 5SU1354-3KK40 is an RCBO that combines overcurrent and earth-leakage protection in one unit. They are not drop-in substitutes; the 5SU1354-3KK40 adds Type F RCD functionality that the 5SL6550-7BB lacks.

What compliance documentation does this brand provide for 5SU1354-3KK40?

The part carries approvals per EN 60898 and IEC 60947-2, and is designated as halogen-free and silicon-free. Standard Siemens SENTRON documentation includes CE declaration, RoHS and REACH compliance statements available on request.