Siemens 5SU1354-4KK10 — Residual Current Breakers (RCCB/RCBO)

Siemens 5SU1354-4KK10 SENTRON RCBO, C-curve 10A, 10kA

MPN5SU1354-4KK10
Active

Siemens SENTRON RCBO, 1P+N, C-curve, 10 A rated at 30 °C, 10 kA per EN 60898 / 20 kA per IEC 60947-2, 2 modular width units (36 mm), IP20.

StockContact for availability
MOQ1 pcs
Sourced new & surplus through independent channelsListing updated Jul 2026

Specifications

Electrical Ratings

5SU1354-4KK10 — Electrical Ratings
ParameterValue
Number of poles2
Overvoltage categoryIII

Identification

5SU1354-4KK10 — Identification
ParameterValue
Product designationRCBO
Product design / constructionSuper resistant K

Mechanical

5SU1354-4KK10 — Mechanical
ParameterValue
Mounting positionany
Width in modular units2
Maximum75 °C
Minimum-40 °C
Width36 mm
Height90 mm
Depth77 mm
Installation depth70 mm

Environmental

5SU1354-4KK10 — Environmental
ParameterValue
IP degree of protectionIP20, if the distribution board is installed, with connected conductors

Electrical

5SU1354-4KK10 — Electrical
ParameterValue
Tripping Characteristic ClassC

Product details

What this RCBO carries and where it fits

The Siemens 5SU1354-4KK10 is a 1P+N residual current operated circuit breaker (RCBO) from the SENTRON Super Resistant K line, combining overcurrent and earth-fault protection in a single 2-module-width (36 mm) package. Rated 10 A at 30 °C with a C tripping characteristic, it handles the inrush of motor starters, contactor coils, and small transformers without nuisance trips on start-up. Breaking capacity is 10 kA per EN 60898 and 20 kA per IEC 60947-2 — the higher figure matters when the device sits downstream of a transformer or in an industrial panel where fault current can exceed the domestic standard. Overvoltage category III and pollution degree 2 confirm it for fixed-installation distribution boards, not plug-in portable use.

Temperature derating — the real current limit

The 10 A rating holds only at 30 °C ambient. At 40 °C it derates to 9.5 A, at 50 °C to 9 A, and at 70 °C to 8 A. If the panel runs warm — and most industrial enclosures do — size the load against the derated figure, not the label. The mounting position is unrestricted, but the IP20 rating assumes the distribution board is installed with conductors connected; open-back enclosures void that protection.

Panel fit and wiring

At 36 mm wide (2 MW) and 77 mm deep (70 mm installation depth), it occupies standard DIN-rail space — two adjacent 18 mm slots. Supply can enter from top or bottom, which simplifies busbar routing in a crowded enclosure. Halogen-free and silicon-free construction matters for clean-room or semiconductor-adjacent panels where outgassing contaminants can't be tolerated.

Frequently asked questions

Where can I buy 5SU1354-4KK10 and how is it quoted?

This part is sourced to order through independent distribution. Submit an RFQ for current pricing and availability — confirmed at quote time, not listed here.

What is the depth and width of 5SU1354-4KK10?

Depth is 77 mm (70 mm installation depth behind the panel face), width is 36 mm (2 modular width units).

Will 5SU1354-4KK10 drop into a panel designed for 5SL6550-7BB?

Physically yes — both are 2 MW wide. But the 5SL6550-7BB is a plain MCB with no residual-current function; swapping in the RCBO adds earth-fault protection but requires the neutral connection that an MCB-only panel may not have wired.

What compliance documentation is available for 5SU1354-4KK10?

The device is rated per EN 60898 (10 kA) and IEC 60947-2 (20 kA), carries overvoltage category III and pollution degree 2, and is halogen-free and silicon-free. Standard Siemens SENTRON declarations of conformity cover RoHS and REACH compliance.

MPN
5SU1354-4KK10