Siemens 5SU1354-4KK25 — Residual Current Breakers (RCCB/RCBO)

Siemens 5SU1354-4KK25 SENTRON RCBO, 2P, 25 A, 30 mA, Type F,

MPN5SU1354-4KK25
Active

Siemens SENTRON 5SU1354-4KK25 RCBO, 2-pole, 25 A rated, 30 mA residual current, Type F, C-curve, 10 kA per EN 60898, 2 MW, IP20.

StockContact for availability
MOQ1 pcs
Sourced new & surplus through independent channelsListing updated Jul 2026

Specifications

Electrical Ratings

5SU1354-4KK25 — Electrical Ratings
ParameterValue
Number of poles2
Overvoltage categoryIII

Identification

5SU1354-4KK25 — Identification
ParameterValue
Product designationRCBO
Product design / constructionSuper resistant K

Mechanical

5SU1354-4KK25 — Mechanical
ParameterValue
Mounting positionany
Width in modular units2
Maximum75 °C
Minimum-40 °C
Width36 mm
Height90 mm
Depth77 mm
Installation depth70 mm

Environmental

5SU1354-4KK25 — Environmental
ParameterValue
IP degree of protectionIP20, if the distribution board is installed, with connected conductors

Electrical

5SU1354-4KK25 — Electrical
ParameterValue
Tripping Characteristic ClassC

Product details

What this RCBO is and where it fits

The Siemens 5SU1354-4KK25 is a 2-pole SENTRON RCBO — residual current circuit breaker with integral overcurrent protection — rated 25 A at 230/400 V AC, 50/60 Hz, with a 30 mA residual trip and Type F characteristic. The C-curve tripping characteristic (5–10× In) handles motor inrush and moderate inductive loads common in industrial control panels. Type F residual current detection covers AC sinusoidal, pulsating DC, and high-frequency AC components — the kind of leakage you get from VFD-fed motors, switched-mode supplies, and modern LED drivers. That makes this unit a better fit for mixed-load final subcircuits than a standard Type A RCBO. Snaps onto a standard DIN rail; 2 modular width units (36 mm) leave room for adjacent breakers. Depth of 77 mm (70 mm installation depth) fits most distribution boards.

Breaking capacity and thermal derating

Rated short-circuit breaking capacity is 10 kA per EN 60898 — sufficient for most residential and commercial final circuits where the prospective fault current stays under that threshold. Overvoltage category III and pollution degree 2 align with fixed-installation switchgear. The 25 A rating holds at 30 °C ambient. At 40 °C it derates to 23.5 A; at 50 °C to 21.75 A; at 60 °C to 20.25 A; at 70 °C to 18.25 A. If the panel ambient runs above 40 °C, factor the derating into your load schedule — the listed values are per the manufacturer's thermal curve.

Mounting and wiring notes

Mounting position is any — vertical, horizontal, or upside-down on the DIN rail. Supply feed can enter from top or bottom, which simplifies busbar routing in multi-row boards. Touch protection is built in (finger-safe terminals).

MPN
5SU1354-4KK25