Siemens 5SU1354-6GV16 — Residual Current Breakers (RCCB/RCBO)

Siemens 5SU1354-6GV16 SENTRON RCBO, B-Curve 16 A, 10 kA, 2P

MPN5SU1354-6GV16
Active

Siemens SENTRON RCBO, B-curve, 16 A, 10 kA (EN 60898) / 20 kA (IEC 60947-2), 1P+N, 2 MW, IP20, 77 x 36 x 90 mm.

Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & sourcing agent· Listing updated Sep 2026

Specifications

5SU1354-6GV16 — Electrical Ratings
ParameterValue
Number of poles2
Overvoltage categoryIII
5SU1354-6GV16 — Identification
ParameterValue
Product designationRCBO
Product design / constructionInstantaneous
5SU1354-6GV16 — Mechanical
ParameterValue
Mounting positionany
Width in modular units2
Maximum75 °C
Minimum-40 °C
Width36 mm
Height90 mm
Depth77 mm
Installation depth70 mm
5SU1354-6GV16 — Environmental
ParameterValue
IP degree of protectionIP20, if the distribution board is installed, with connected conductors
5SU1354-6GV16 — Electrical
ParameterValue
Tripping Characteristic ClassB

Product details

It combines a B-curve overcurrent trip at 16 A with an integrated residual current device in a single 1P+N pole configuration — one protected pole plus a switched neutral.

B-curve and thermal derating

At a 30 °C ambient the unit carries 16 A continuously; at 40 °C it derates to 15.2 A, at 50 °C to 14.4 A, and at 70 °C to 12.32 A. This thermal derating curve means the installer must account for enclosure heat rise when loading the circuit near the nominal rating, particularly in densely populated distribution boards.

The housing measures 77 mm deep by 36 mm wide by 90 mm tall, occupying 2 modular-width units (MW) on a standard DIN rail. Installation depth is 70 mm. IP20 protection applies once the distribution board is installed with conductors connected — this is an enclosed-panel device, not rated for exposed or washdown environments.

Frequently asked questions

Where can I buy the 5SU1354-6GV16 and what is the lead time?

The 5SU1354-6GV16 is sourced and quoted to order against an RFQ through independent distribution. Availability and current pricing are confirmed at the time of quotation.

What is the breaking capacity of the 5SU1354-6GV16?

The RCBO is rated 10 kA according to EN 60898 and 20 kA according to IEC 60947-2, covering the two common standards for final-circuit protection.

What is the difference between the 5SU1354-6GV16 and the 5SL6516-6YA?

The 5SL6516-6YA is a Siemens SENTRON MCB (overcurrent only), while the 5SU1354-6GV16 is an RCBO combining overcurrent and residual-current protection in one unit. The 5SU1354-6GV16 cannot be replaced by a bare MCB when earth-fault protection is required.

What compliance documentation is available for the 5SU1354-6GV16?

The unit is halogen-free and silicon-free. It carries a rated insulation voltage of 264 V, overvoltage category III, and pollution degree 2. The listed standards are EN 60898 and IEC 60947-2.

MPN
5SU1354-6GV16