Siemens 5SU1354-7GV10 — Residual Current Breakers (RCCB/RCBO)

Siemens 5SU1354-7GV10 SENTRON RCBO, 10 A, 10 kA, Type C

MPN5SU1354-7GV10
Active

Siemens SENTRON RCBO, 1P+N, 10 A at 30 °C, Type C tripping characteristic, 10 kA (EN 60898) / 20 kA (IEC 60947-2), 230/240 V AC, 50 Hz, 2 MW, IP20.

StockContact for availability
MOQ1 pcs
Sourced new & surplus through independent channelsListing updated Jul 2026

Specifications

Electrical Ratings

5SU1354-7GV10 — Electrical Ratings
ParameterValue
Number of poles2
Overvoltage categoryIII

Identification

5SU1354-7GV10 — Identification
ParameterValue
Product designationRCBO
Product design / constructionInstantaneous

Mechanical

5SU1354-7GV10 — Mechanical
ParameterValue
Mounting positionany
Width in modular units2
Maximum75 °C
Minimum-40 °C
Width36 mm
Height90 mm
Depth77 mm
Installation depth70 mm

Environmental

5SU1354-7GV10 — Environmental
ParameterValue
IP degree of protectionIP20, if the distribution board is installed, with connected conductors

Electrical

5SU1354-7GV10 — Electrical
ParameterValue
Tripping Characteristic ClassC

Product details

Siemens 5SU1354-7GV10 — SENTRON RCBO, 10 A, Type C, 10 kA

The Siemens 5SU1354-7GV10 is a SENTRON RCBO (residual current circuit breaker with overcurrent protection) in a 1P+N, 2-pole design, rated 10 A at 30 °C with a Type C tripping characteristic. It occupies 2 modular width units (36 mm) on a DIN rail and can be fed from either top or bottom, with any mounting position accepted. The Type C curve trips between 5 and 10 times rated current, making it suitable for circuits with moderate inrush — motorized loads, small transformers, or lighting banks where the start-up surge would nuisance-trip a Type B. The 10 kA breaking capacity per EN 60898 covers most domestic and light commercial panel duties; the 20 kA rating per IEC 60947-2 gives headroom for industrial distribution boards where fault currents run higher. Rated voltage is 230/240 V AC at 50 Hz, with an insulation voltage (Ui) of 264 V and surge voltage resistance of 4 kV. Overvoltage category III and pollution degree 2 mean it's rated for fixed installation in building distribution panels, not for outdoor or wet locations — the IP20 rating (with connected conductors and installed distribution board) confirms indoor use only.

Thermal derating and real-world current

The 10 A rating at 30 °C derates linearly as ambient temperature rises: 9.5 A at 40 °C, 9.3 A at 45 °C, 9 A at 50 °C, 8.7 A at 55 °C, 8.5 A at 60 °C, 8.2 A at 65 °C, and 8 A at 70 °C. In a crowded panel where internal temperature hits 50 °C, the effective continuous current drops to 9 A — factor that into your load calculation rather than relying on the 30 °C nameplate figure.

Integration and panel fit

Dimensions are 77 mm depth, 36 mm width (2 MW), 90 mm height, with an installation depth of 70 mm. The 36 mm width matches standard DIN-rail modular devices — it occupies the same footprint as two single-pole MCBs side by side. The IP20 rating means the distribution board must be closed and conductors connected for the protection to be effective; this is normal for panelboard installation, not a standalone enclosure.

Frequently asked questions

Where can I buy 5SU1354-7GV10 and how do I get a price?

This part is sourced and quoted to order against an RFQ through independent distribution. Availability and current pricing are confirmed at quote time — submit an RFQ for a landed-cost figure.

What is 5SU1354-7GV10's listed depth (77 mm) on this component line?

The depth is 77 mm, with an installation depth of 70 mm. Width is 36 mm (2 modular units), height is 90 mm.

What compliance documentation does this brand provide for 5SU1354-7GV10 (RoHS, REACH, UL, IEC)?

The part is halogen-free and silicon-free, which supports RoHS and REACH compliance. It is rated per EN 60898 (10 kA) and IEC 60947-2 (20 kA). Specific UL or other jurisdictional certificates should be requested with your RFQ — the evidence does not list them directly.