Siemens 5SU1354-7LB10 — Residual Current Breakers (RCCB/RCBO)

Siemens 5SU1354-7LB10 SENTRON RCBO, 10A C-curve 1P+N, 10kA E

MPN5SU1354-7LB10
Active

Siemens SENTRON 5SU1354-7LB10 RCBO, 1P+N, C-curve 10 A, 10 kA (EN 60898) / 20 kA (IEC 60947-2), short-time delayed G, super resistant K, 2 MW, halogen-free.

Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & sourcing agent· Listing updated Sep 2026

Specifications

5SU1354-7LB10 — Electrical Ratings
ParameterValue
Number of poles2
Overvoltage categoryIII
5SU1354-7LB10 — Identification
ParameterValue
Product designationRCBO
Product design / constructionShort-time delayed G, super resistant K
5SU1354-7LB10 — Mechanical
ParameterValue
Mounting positionany
Width in modular units2
Maximum75 °C
Minimum-40 °C
Width36 mm
Height90 mm
Depth77 mm
Installation depth70 mm
5SU1354-7LB10 — Environmental
ParameterValue
IP degree of protectionIP20, if the distribution board is installed, with connected conductors
5SU1354-7LB10 — Electrical
ParameterValue
Tripping Characteristic ClassC

Product details

The Siemens 5SU1354-7LB10 is a SENTRON RCBO — a combined residual-current and overcurrent protective device in a single 2-module-width (36 mm) package, 1P+N pole configuration with one protected pole. It is designed for final circuits in distribution boards where both earth-leakage and short-circuit/overload protection are required in one unit, saving a DIN-rail position compared to separate RCCB and MCB. The design is marked "Short-time delayed G, super resistant K" — the residual-current element is a G-type (short-time delayed, typically 10 ms minimum non-tripping time) to avoid nuisance tripping from transient leakage pulses common on electronic loads, and the K suffix indicates enhanced immunity to surge currents (lightning or switching surges) without false operation.

The 10 A rating is only valid at 30 °C ambient inside the distribution board. Per the datasheet derating table, at 40 °C the continuous current drops to 9.5 A, at 50 °C to 9 A, at 60 °C to 8.5 A, and at 70 °C to 7.7 A. If your panel runs warm — common in crowded enclosures or near transformers — size the upstream protection and the connected load against the derated figure, not the 30 °C nameplate.

Environmental and compliance profile

Frequently asked questions

What is the breaking capacity of the 5SU1354-7LB10?

10 kA per EN 60898 and 20 kA per IEC 60947-2. The higher IEC rating applies under the manufacturer's specified installation conditions.

What does the 'short-time delayed G, super resistant K' designation mean?

G-type means the residual current element has a short time delay (typically 10 ms minimum non-tripping time) to avoid nuisance trips from transient leakage. K-type means enhanced immunity to surge currents from lightning or switching events.

Where can I buy the 5SU1354-7LB10?

Sourced and quoted to order against an RFQ through independent distribution. Availability and current pricing are confirmed at quote time.