Skip to main content
Siemens 5SU1354-7VK20 — Residual Current Breakers (RCCB/RCBO)

Siemens 5SU1354-7VK20 SENTRON RCBO, 20 A, 30 mA, Type A, 2-p

MPN5SU1354-7VK20

Siemens SENTRON 5SU1354-7VK20, RCBO, 2-pole (1P+N), 20 A, 30 mA, Type A, tripping characteristic C, 10 kA / 20 kA, 2 MW, IP20.

Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & sourcing agent· Listing updated Sep 2026

Specifications

5SU1354-7VK20 — Electrical Ratings
ParameterValue
Number of poles2
Overvoltage categoryIII
5SU1354-7VK20 — Identification
ParameterValue
Product designationRCBO
Product design / constructionSuper resistant K
5SU1354-7VK20 — Mechanical
ParameterValue
Mounting positionany
Width in modular units2
Maximum75 °C
Minimum-40 °C
Width36 mm
Height90 mm
Depth77 mm
Installation depth70 mm
5SU1354-7VK20 — Environmental
ParameterValue
IP degree of protectionIP20, if the distribution board is installed, with connected conductors
5SU1354-7VK20 — Electrical
ParameterValue
Tripping Characteristic ClassC
Operational current / at AC / rated value20 A

Product details

What this RCBO covers

The Siemens SENTRON 5SU1354-7VK20 is a 2-pole (1P+N) RCBO — residual current circuit breaker with overcurrent protection — rated 20 A at 230/240 V AC, 50/60 Hz. The 30 mA residual-current trip and Type A sensitivity mean it detects sinusoidal AC faults plus pulsating DC faults up to 6 mA smooth DC, which covers most modern electronics and variable-speed drives on the protected circuit. Tripping characteristic C (magnetic release at 5–10× In) handles motor inrush and capacitive loads without nuisance tripping, while the 10 kA breaking capacity per EN 60898 and 20 kA per IEC 60947-2 give it headroom for commercial and light industrial panels where fault currents stay under 10 kA at the service entrance.

Depth is 77 mm, installation depth 70 mm — fits standard 80 mm deep enclosures. Mounting position any, so it can go sideways or inverted in tight sub-distribution boards. Rated IP20 once the distribution board is installed and conductors connected; that means dry, indoor locations only.

Frequently asked questions

What are the key ratings for 5SU1354-7VK20?

Rated 20 A at 230/240 V AC, 30 mA residual current, Type A, tripping characteristic C, breaking capacity 10 kA per EN 60898 and 20 kA per IEC 60947-2.

Will 5SU1354-7VK20 drop into a panel specified for 5SU9354-7KK16 without rewiring?

Both are 2-module-width (36 mm) SENTRON RCBOs on the same DIN-rail footprint, so the mechanical fit is identical. The difference is in the electrical ratings — verify that the 20 A / 30 mA / Type A / C curve of the 5SU1354-7VK20 matches the circuit requirements of the original 5SU9354-7KK16 before swapping.

Where can I buy 5SU1354-7VK20 and what is the lead time?

Sourced and quoted to order against an RFQ through independent distribution. Availability and current pricing are confirmed at quote time — submit an inquiry for a firm lead time.

MPN
5SU1354-7VK20