Siemens 5SU1356-0KK13 — Residual Current Breakers (RCCB/RCBO)

Siemens 5SU1356-0KK13 SENTRON RCBO, 13 A, 30 mA, Type AC, B

MPN5SU1356-0KK13

Siemens SENTRON 5SU1356-0KK13 RCBO, 2-pole, 13 A rated current, 30 mA residual fault, Type AC, tripping characteristic B, 6 kA breaking capacity per EN 60898.

StockContact for availability
MOQ1 pcs
Sourced new & surplus through independent channelsListing updated Jul 2026

Specifications

Electrical Ratings

5SU1356-0KK13 — Electrical Ratings
ParameterValue
Number of poles2
Overvoltage categoryIII

Identification

5SU1356-0KK13 — Identification
ParameterValue
Product designationRCBO
Product design / constructionInstantaneous

Mechanical

5SU1356-0KK13 — Mechanical
ParameterValue
Mounting positionany
Width in modular units2
Maximum75 °C
Minimum-40 °C
Width36 mm
Height90 mm
Depth77 mm
Installation depth70 mm

Environmental

5SU1356-0KK13 — Environmental
ParameterValue
IP degree of protectionIP20, if the distribution board is installed, with connected conductors

Electrical

5SU1356-0KK13 — Electrical
ParameterValue
Tripping Characteristic ClassB

Product details

What it is and what it protects

The Siemens 5SU1356-0KK13 is a 2-pole RCBO (residual current circuit breaker with overcurrent protection) from the SENTRON series, combining a 13 A overcurrent trip with a 30 mA residual-current device in one 36 mm-wide module. The overcurrent side uses a B tripping characteristic (trips at 3–5× rated current for short circuits), and the residual side is Type AC — sensitive to sinusoidal AC fault currents only, not pulsed DC or smooth DC. Breaking capacity is 6 kA per EN 60898, adequate for most residential and light commercial distribution boards.

Thermal derating — where the 13 A rating holds and where it drops

The 13 A rating is valid at 30 °C ambient. At 40 °C it derates to 12.48 A, at 50 °C to 11.96 A, and at 60 °C to 11.31 A. At 70 °C the continuous current drops to 10.01 A — roughly 77% of the nominal value. If this RCBO feeds a continuous 13 A load in a 50 °C panel interior, the breaker will nuisance-trip on thermal overload. Size the load or the ambient before locking the BOM.

Mounting and integration into a distribution board

The 5SU1356-0KK13 occupies 2 modular width units (36 mm) on a DIN rail. Mounting position is any orientation — no derating for horizontal or inverted fit. Installation depth is 70 mm behind the panel face, with an overall depth of 77 mm including the front projection. Supply can enter from top or bottom. IP20 rating applies once installed in a distribution board with connected conductors — meaning the busbar and wiring enclosure provide the touch protection; the device alone is finger-safe only when panel-mounted. Halogen-free and silicon-free construction matters for environments where off-gassing during a fault could contaminate sensitive electronics.

Frequently asked questions

What is the breaking capacity of 5SU1356-0KK13?

The breaking capacity is 6 kA rated per EN 60898, which covers standard residential and light commercial fault levels.

What is the residual current rating and type?

The residual trip threshold is 30 mA, Type AC — meaning it detects sinusoidal AC fault currents only. Not suitable for circuits with variable-speed drives or LED drivers that generate pulsed or smooth DC fault currents.

How do I get current pricing and availability for 5SU1356-0KK13?

Submit an RFQ through the storefront. Availability and current pricing are confirmed at quote time; this part is sourced through independent distribution channels.