Skip to main content
Siemens 5SU1356-0KK25 — Residual Current Breakers (RCCB/RCBO)

Siemens 5SU1356-0KK25 SENTRON RCBO, 25A B-Curve 2-Pole 6kA

MPN5SU1356-0KK25

Siemens SENTRON 5SU1356-0KK25, RCBO, 2-pole (1P+N), 25 A, B-curve, Type AC, 6 kA per EN 60898, 15 kA per IEC 60947-2, 36 mm (2 MW).

Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & sourcing agent· Listing updated Sep 2026

Specifications

5SU1356-0KK25 — Electrical Ratings
ParameterValue
Number of poles2
Overvoltage categoryIII
5SU1356-0KK25 — Identification
ParameterValue
Product designationRCBO
Product design / constructionInstantaneous
5SU1356-0KK25 — Mechanical
ParameterValue
Mounting positionany
Width in modular units2
Maximum75 °C
Minimum-40 °C
Width36 mm
Height90 mm
Depth77 mm
Installation depth70 mm
5SU1356-0KK25 — Environmental
ParameterValue
IP degree of protectionIP20, if the distribution board is installed, with connected conductors
5SU1356-0KK25 — Electrical
ParameterValue
Tripping Characteristic ClassB

Product details

The Siemens 5SU1356-0KK25 is a SENTRON RCBO combining overcurrent protection and residual current detection in a single 2-module-width (36 mm) package. Breaking capacity is 6 kA per EN 60898 and 15 kA per IEC 60947-2 — the higher figure applies when the RCBO is used as a distribution board main or where the prospective fault current exceeds 6 kA. The 1P+N configuration switches the phase only; the neutral is switched internally for isolation but not protected against overcurrent.

At 30 °C ambient the unit carries the full 25 A; at 40 °C it derates to 23.5 A, at 50 °C to 21.75 A, and at 70 °C to 18.25 A. Mounting position is unrestricted, and the supply can enter from top or bottom, which simplifies busbar routing in a distribution board. Installation depth is 70 mm (77 mm overall), fitting standard flush-mount enclosures. IP20 applies only with the distribution board closed and conductors connected — the front face is finger-safe, but the terminals are not touch-proof with the cover open.

Frequently asked questions

What is the breaking capacity of 5SU1356-0KK25?

6 kA per EN 60898 and 15 kA per IEC 60947-2. The 15 kA rating applies when the device is used under the industrial standard, which covers higher prospective fault currents than the domestic EN 60898 test sequence.

What does the B-curve mean on this RCBO?

B-curve means the magnetic trip operates at 3 to 5 times the rated current (75–125 A for this 25 A unit). It's intended for resistive or general-purpose loads with low inrush — lighting, socket circuits, small appliances — rather than motor or transformer feeders that would need a C or D curve.

Where can I buy 5SU1356-0KK25?

Sourced and quoted to order against an RFQ through independent distribution channels. Availability and current pricing are confirmed at quote time — no stock or price figures are published here.

MPN
5SU1356-0KK25