Siemens SENTRON 5SU1356-0KK40 RCBO 2-pole 40 A Type B 6 kA

MPN5SU1356-0KK40

Siemens SENTRON 5SU1356-0KK40 RCBO, 2-pole (1P+N), 40 A rated, Type B tripping characteristic, 6 kA (EN 60898) / 10 kA (IEC 60947-2), residual current type AC, instantaneous design.

StockContact for availability
MOQ1 pcs
Sourced new & surplus through independent channelsListing updated Jul 2026

Specifications

Electrical Ratings

5SU1356-0KK40 — Electrical Ratings
ParameterValue
Number of poles2
Overvoltage categoryIII

Identification

5SU1356-0KK40 — Identification
ParameterValue
Product designationRCBO
Product design / constructionInstantaneous

Mechanical

5SU1356-0KK40 — Mechanical
ParameterValue
Mounting positionany
Width in modular units2
Maximum75 °C
Minimum-40 °C
Width36 mm
Height90 mm
Depth77 mm
Installation depth70 mm

Environmental

5SU1356-0KK40 — Environmental
ParameterValue
IP degree of protectionIP20, if the distribution board is installed, with connected conductors

Electrical

5SU1356-0KK40 — Electrical
ParameterValue
Tripping Characteristic ClassB

Product details

What this RCBO is and what it does

The Siemens SENTRON 5SU1356-0KK40 is a 2-pole (1P+N) residual current operated circuit breaker (RCBO) combining overcurrent protection and residual current detection in a single 36 mm wide (2 modular width units) device for 50 Hz systems. Rated 40 A at 30 °C with a Type B tripping characteristic, it interrupts overcurrents per EN 60898 up to 6 kA and per IEC 60947-2 up to 10 kA, with a residual current type AC (sinusoidal) — suited for general-purpose final circuits in residential and commercial distribution boards. The RCBO mounts in any position, accepts supply from either top or bottom, and carries an IP20 rating once installed in a distribution board with connected conductors.

Temperature derating — what the 40 A rating actually means in a warm panel

The 40 A rating is at 30 °C ambient. At 40 °C the continuous current drops to 37.6 A, at 50 °C to 34.8 A, and at 70 °C to 29.2 A. If the distribution board sits in a warm environment or is tightly packed, size the load side accordingly — the nameplate 40 A is not the usable figure at elevated panel temperature.

Panel integration and physical fit

Width of 36 mm (2 MW), depth of 77 mm, and installation depth of 70 mm. Fits standard DIN-rail distribution boards; the 70 mm installation depth means it clears most domestic and light commercial enclosure depths without modification.

Frequently asked questions

How do I get current pricing and availability for 5SU1356-0KK40?

Submit an RFQ through this listing. Availability and current pricing are confirmed at quote time; the part is sourced to order through independent distribution.

What is 5SU1356-0KK40's listed depth (77 mm) on this component line?

Depth is 77 mm, with an installation depth of 70 mm. Width is 36 mm (2 modular width units), height is 90 mm.

What compliance documentation does this brand provide for 5SU1356-0KK40 (RoHS, REACH, UL, IEC)?

The RCBO is designed per EN 60898 (6 kA) and IEC 60947-2 (10 kA), halogen-free and silicon-free. Specific RoHS/REACH declarations are manufacturer-provided; request them with your RFQ.