Siemens 5SU1356-1KK16 — Residual Current Breakers (RCCB/RCBO)

Siemens 5SU1356-1KK16 SENTRON RCBO, 16 A, 6 kA, Type C, 1P+N

MPN5SU1356-1KK16

Siemens SENTRON 5SU1356-1KK16 RCBO, 1P+N, 16 A at 30 °C, Type C, 6 kA (EN 60898) / 15 kA (IEC 60947-2), 50 Hz, 2 MW, IP20.

$34.29Ref. price · indicative, final on quote
Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & sourcing agent· Listing updated Sep 2026

Specifications

5SU1356-1KK16 — Electrical Ratings
ParameterValue
Number of poles2
Overvoltage categoryIII
5SU1356-1KK16 — Identification
ParameterValue
Product designationRCBO
Product design / constructionInstantaneous
5SU1356-1KK16 — Mechanical
ParameterValue
Mounting positionany
Width in modular units2
Maximum75 °C
Minimum-40 °C
Width36 mm
Height90 mm
Depth77 mm
Installation depth70 mm
5SU1356-1KK16 — Environmental
ParameterValue
IP degree of protectionIP20, if the distribution board is installed, with connected conductors
5SU1356-1KK16 — Electrical
ParameterValue
Tripping Characteristic ClassC

Product details

The Siemens 5SU1356-1KK16 is a SENTRON RCBO — a combined residual-current circuit breaker with overcurrent protection — in a 1P+N, 2-module-width (36 mm) package for DIN-rail panels. It carries a 16 A rating at 30 °C ambient, with a Type C tripping characteristic (magnetic release between 5 and 10 times In) for moderate inrush loads like small motors or lighting banks. The interrupting capacity is 6 kA per EN 60898 and 15 kA per IEC 60947-2, covering most commercial and light industrial fault levels.

The 16 A rating holds at 30 °C; above that, the continuous current must be derated per the listed curve: 15.2 A at 40 °C, 14.88 A at 45 °C, 14.4 A at 50 °C, 13.92 A at 55 °C, 13.6 A at 60 °C, 12.96 A at 65 °C, and 12.32 A at 70 °C. Rated voltage is 230/240 V AC at 50 Hz. Insulation voltage (Ui) is 264 V, and surge voltage resistance is 4 kV, consistent with overvoltage category III and pollution degree 2 — standard for fixed-installation distribution boards.

Two modular width units (36 mm) occupy the rail.

Frequently asked questions

Will 5SU1356-1KK16 drop into a panel that was specified around 5SU9354-7KK16 without rewiring?

Both are 2-module-width (36 mm) DIN-rail RCBOs with 1P+N pole configuration, so the mechanical fit and busbar connection points are identical. No rewiring is needed for the panel cutout or busbar. However, confirm that the rated current, tripping characteristic, and breaking capacity of the 5SU1356-1KK16 match the circuit design before swapping.