Siemens 5SU1356-6GV10 — Residual Current Breakers (RCCB/RCBO)

Siemens 5SU1356-6GV10 SENTRON RCBO, 2P, 10 A, B-Curve, Type

MPN5SU1356-6GV10
Active

Siemens SENTRON 5SU1356-6GV10, RCBO, 2-pole, 10 A rated, B-curve, Type A residual current, 6 kA (EN 60898) / 15 kA (IEC 60947-2), 2 modular width units.

StockContact for availability
MOQ1 pcs
Sourced new & surplus through independent channelsListing updated Jul 2026

Specifications

Electrical Ratings

5SU1356-6GV10 — Electrical Ratings
ParameterValue
Number of poles2
Overvoltage categoryIII

Identification

5SU1356-6GV10 — Identification
ParameterValue
Product designationRCBO
Product design / constructionInstantaneous

Mechanical

5SU1356-6GV10 — Mechanical
ParameterValue
Mounting positionany
Width in modular units2
Maximum75 °C
Minimum-40 °C
Width36 mm
Height90 mm
Depth77 mm
Installation depth70 mm

Environmental

5SU1356-6GV10 — Environmental
ParameterValue
IP degree of protectionIP20, if the distribution board is installed, with connected conductors

Electrical

5SU1356-6GV10 — Electrical
ParameterValue
Tripping Characteristic ClassB

Product details

What this RCBO is and what it does

The Siemens 5SU1356-6GV10 is a 2-pole RCBO (residual current circuit breaker with overcurrent protection) from the SENTRON series, combining a B-curve MCB and a Type A RCD in a single 36 mm wide (2 MW) unit. It's rated 10 A at 30 °C with a 6 kA breaking capacity per EN 60898 and 15 kA per IEC 60947-2, so it handles both overcurrent and earth-fault protection in one DIN-rail footprint — no separate RCD needed downstream.

Ratings that matter for panel fit

The B-curve trips between 3 and 5 times rated current — standard for resistive and general-purpose loads where you don't want nuisance trips from motor inrush. Type A residual current detection catches pulsating DC fault currents from electronics and single-phase rectifiers, which a plain AC type would miss. At 40 °C ambient the continuous rating derates to 9.5 A; at 50 °C it's 9 A. If the panel runs hot — say above 55 °C — plan for 8.7 A or less. The 77 mm depth and 36 mm width (2 MW) mean it fits standard 18 mm/module DIN-rail enclosures; supply can land top or bottom. IP20 with the distribution board installed and conductors connected — standard for enclosed panel use, not for wet or outdoor locations.

Frequently asked questions

What is the breaking capacity of 5SU1356-6GV10?

6 kA per EN 60898 and 15 kA per IEC 60947-2 — the higher figure applies when the installation standard allows the IEC 60947-2 rating.

Will 5SU1356-6GV10 drop into a panel specified around 5SY5202-6 without rewiring?

The 5SU1356-6GV10 is an RCBO (combined RCD+MCB), while 5SY5202-6 is a standalone MCB. They serve different protection functions — the RCBO adds residual current detection that the MCB alone doesn't provide. Physical dimensions differ; verify DIN-rail space and wiring topology before substituting.

Where can I buy 5SU1356-6GV10?

Sourced and quoted to order against an RFQ through independent distribution. Availability and current pricing are confirmed at quote time.