Siemens 5SU1356-7GV06 — Residual Current Breakers (RCCB/RCBO)

Siemens 5SU1356-7GV06 SENTRON RCBO, Type A 30mA C6 6kA, 1P+N

MPN5SU1356-7GV06
Active

Siemens SENTRON 5SU1 RCBO, Type A 30mA, tripping characteristic C, rated current 6 A, breaking capacity 6 kA (EN 60898) / 25 kA (IEC 60947-2), 1P+N, 2 modular width units, IP20.

StockContact for availability
MOQ1 pcs
Sourced new & surplus through independent channelsListing updated Jul 2026

Specifications

Electrical Ratings

5SU1356-7GV06 — Electrical Ratings
ParameterValue
Number of poles2
Overvoltage categoryIII

Identification

5SU1356-7GV06 — Identification
ParameterValue
Product designationRCBO
Product design / constructionInstantaneous

Mechanical

5SU1356-7GV06 — Mechanical
ParameterValue
Mounting positionany
Width in modular units2
Maximum75 °C
Minimum-40 °C
Width36 mm
Height90 mm
Depth77 mm
Installation depth70 mm

Environmental

5SU1356-7GV06 — Environmental
ParameterValue
IP degree of protectionIP20, if the distribution board is installed, with connected conductors

Electrical

5SU1356-7GV06 — Electrical
ParameterValue
Tripping Characteristic ClassC

Product details

The Siemens 5SU1356-7GV06 is a SENTRON RCBO — a combined residual-current circuit breaker with overcurrent protection — in a Type A, 30 mA sensitivity, C6 curve configuration. It occupies 2 modular width units (36 mm) on a DIN rail and is rated for 230/240 V AC at 50 Hz. The 6 kA breaking capacity per EN 60898 covers residential and light commercial panelboards; the 25 kA rating per IEC 60947-2 gives headroom for industrial distribution where higher prospective fault currents exist.

What the ratings mean for fit

Type A detection trips on sinusoidal AC and pulsating DC residual currents up to 6 mA smooth DC. The 30 mA sensitivity is standard for personal protection against direct contact. The C6 curve (C characteristic, 6 A rated) means magnetic trip occurs at 5 to 10 times In (30–60 A), suited for circuits with moderate inrush — lighting banks, small motor loads, socket outlets. The 1P+N design switches the phase and switches the neutral via a linked mechanism, but only the phase is protected against overcurrent; the neutral pole is switched but not monitored for overload. Two modular width units (36 mm wide, 77 mm deep, 90 mm tall) fit standard DIN-rail enclosures. Mounting position is any, so horizontal or vertical panel layouts are fine. IP20 with connected conductors means it is protected against solid objects >12 mm but not against moisture — install inside a distribution board with a sealed door.

Panel integration notes

Supply can enter from top or bottom — no mandatory orientation for line/load. The 70 mm installation depth leaves clearance behind the DIN rail for wiring. Halogen-free and silicon-free construction matters for clean-room or high-reliability environments where outgassing or contamination is a concern. Mechanical service life is 10,000 operating cycles typical. For frequent switching duty, consider a dedicated switch-disconnector ahead of the RCBO.

Frequently asked questions

Will 5SU1356-7GV06 drop into a panel specified around 5SL6550-7BB without rewiring?

Physically yes — both are 2 MW (36 mm wide), same depth (77 mm vs 76 mm), same DIN-rail clip, same top/bottom feed. But the 5SL6550-7BB is an MCB with no residual-current function; swapping in an RCBO adds the neutral connection and changes the wiring scheme. The panel must have a neutral bar accessible for the RCBO's neutral pigtail.