Siemens 5SU1356-7KK40 — Residual Current Breakers (RCCB/RCBO)

Siemens 5SU1356-7KK40 SENTRON RCBO, 40 A, 6 kA, Type C, 1P+N

MPN5SU1356-7KK40
Active

Siemens SENTRON 5SU1356-7KK40 RCBO, 1P+N, Type C, 40 A at 30 °C, 6 kA per EN 60898, 10 kA per IEC 60947-2, instantaneous design, 2 MW, IP20.

StockContact for availability
MOQ1 pcs
Sourced new & surplus through independent channelsListing updated Jul 2026

Specifications

Electrical Ratings

5SU1356-7KK40 — Electrical Ratings
ParameterValue
Number of poles2
Overvoltage categoryIII

Identification

5SU1356-7KK40 — Identification
ParameterValue
Product designationRCBO
Product design / constructionInstantaneous

Mechanical

5SU1356-7KK40 — Mechanical
ParameterValue
Mounting positionany
Width in modular units2
Maximum75 °C
Minimum-40 °C
Width36 mm
Height90 mm
Depth77 mm
Installation depth70 mm

Environmental

5SU1356-7KK40 — Environmental
ParameterValue
IP degree of protectionIP20, if the distribution board is installed, with connected conductors

Electrical

5SU1356-7KK40 — Electrical
ParameterValue
Tripping Characteristic ClassC

Product details

RCBO for single-phase final circuits

The Siemens 5SU1356-7KK40 is a SENTRON RCBO combining overcurrent protection and residual current detection in a single 2-module-wide (36 mm) package. It protects a single-phase (1P+N) circuit with a Type C tripping characteristic — the magnetic release trips between 5 and 10 times In, so it handles motor inrush and lighting ballast start-up without nuisance trips on a 40 A rated load at 30 °C ambient. Breaking capacity is 6 kA per EN 60898 for domestic/commercial distribution boards, and 10 kA per IEC 60947-2 for industrial panel applications — the higher figure gives headroom on fault-current duty in an MCC or sub-distribution board. The part is instantaneous design (no intentional time delay), so it clears high-impedance earth faults fast. Rated insulation voltage (Ui) is 264 V, overvoltage category III, pollution degree 2 — standard for fixed-installation final circuits in building and light industrial distribution. Supply frequency is 50 Hz only; not suitable for 60 Hz networks.

Thermal derating and mounting

The 40 A rating holds only at 30 °C. At 40 °C derate to 37.6 A, at 50 °C to 34.8 A, and at 70 °C to 29.2 A. If the panel ambient runs hot — say a crowded enclosure with drives — size the upstream protection for the derated figure, not the nameplate 40 A. Mounting position is any, and the supply can enter from top or bottom — no orientation restrictions for the residual-current electronics. Installation depth is 70 mm plus conductor bending space; the overall depth of 77 mm includes the front projection. IP20 only, and that assumes the distribution board is closed and conductors are connected. The 2-module (36 mm) width matches standard DIN-rail cutouts. Halogen-free and silicon-free construction — important for environments where outgassing can contaminate contacts or optics.

Frequently asked questions

What is the breaking capacity of 5SU1356-7KK40?

6 kA per EN 60898 for domestic/commercial boards, and 10 kA per IEC 60947-2 for industrial panels.

What is the width and depth of 5SU1356-7KK40?

Width is 36 mm (2 modular units), depth is 77 mm, installation depth is 70 mm.

Where can I buy 5SU1356-7KK40 and how is it quoted?

This part is sourced and quoted to order against an RFQ through independent distribution. Availability and current pricing are confirmed at quote time.

MPN
5SU1356-7KK40