Skip to main content
Siemens 5SU1374-7AK82 — Residual Current Breakers (RCCB/RCBO)

Siemens 5SU1374-7AK82 SENTRON RCBO, 4P, 125 A, 30 mA, C-Char

MPN5SU1374-7AK82
Active

Siemens SENTRON 5SU1374-7AK82, RCBO, 4-pole, 125 A, 30 mA residual current, type B, short-time-delayed K, C-characteristic, 10 kA breaking capacity per EN 60898, 400 V AC.

Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & sourcing agent· Listing updated Sep 2026

Specifications

5SU1374-7AK82 — Electrical Ratings
ParameterValue
Number of poles4
Overvoltage categoryIII
5SU1374-7AK82 — Identification
ParameterValue
Product designationRCBO
Product design / constructionSuper resistant K
5SU1374-7AK82 — Mechanical
ParameterValue
Mounting positionany
Width in modular units11
Maximum75 °C
Minimum-40 °C
Width198 mm
Height90 mm
Depth77 mm
Installation depth70 mm
5SU1374-7AK82 — Environmental
ParameterValue
IP degree of protectionIP20, if the distribution board is installed, with connected conductors
5SU1374-7AK82 — Electrical
ParameterValue
Tripping Characteristic ClassC

Product details

The 30 mA sensitivity covers personnel protection against direct contact (IEC 60364-4-41), while the C-curve handles moderate inrush from motor and lighting loads without nuisance tripping. This is the 'Super resistant K' design variant, built for environments where nuisance tripping from transient surges or lightning-induced currents is a concern — the short-time-delayed K characteristic allows brief high-frequency leakage (like from VFDs or switching supplies) to pass without dropping the load, while still clearing a genuine ground fault at 30 mA.

Panel fit and physical integration

The unit occupies 11 modular width units on a standard DIN rail (198 mm wide, 77 mm deep, 90 mm tall) with an installation depth of 70 mm behind the panel face. The IP20 rating applies once the distribution board is installed and conductors are connected; the board itself provides the environmental seal.

Surge voltage resistance is 4000 V, and the unit handles a 3 kA surge current (8/20 μs waveform), which is the standard impulse for lightning-induced transients on low-voltage mains. Energy limitation class 3 means the RCBO limits let-through energy during a fault, reducing stress on downstream equipment and wiring. The test circuit requires a minimum of 195 V to verify the residual-current function — important to know if you're commissioning on a reduced-voltage supply.

Frequently asked questions

Who supplies 5SU1374-7AK82 and how is it quoted for volume purchases?

The 5SU1374-7AK82 is sourced through independent distribution channels and quoted to order against an RFQ. Availability and current pricing are confirmed at quote time — submit an RFQ for volume pricing and lead time.

What is 5SU1374-7AK82's listed depth?

The 5SU1374-7AK82 has a depth of 77 mm, with an installation depth of 70 mm behind the panel face.

What compliance documentation does the SENTRON brand provide for 5SU1374-7AK82?

The 5SU1374-7AK82 carries ratings per EN 60898 and IEC 60947-2 (both 10 kA breaking capacity), is halogen-free and silicon-free, and is designed for overvoltage category III with pollution degree 2. Standard Siemens SENTRON documentation includes CE declaration of conformity and RoHS compliance information.

Where can I buy 5SU1374-7AK82?

The 5SU1374-7AK82 is available to order through independent distribution channels. Submit an RFQ to confirm current pricing and availability — the part is sourced and quoted on request.

MPN