Skip to main content
Siemens 5SU1374-7DK82 — Residual Current Breakers (RCCB/RCBO)

Siemens 5SU1374-7DK82 SENTRON RCBO, 125 A, 4-pole, Type B+

MPN5SU1374-7DK82
Active

Siemens SENTRON 5SU1 series RCBO, 4-pole, 125 A (at 30 °C), Type B+ fault current, C tripping characteristic, 10 kA breaking capacity per EN 60898 and IEC 60947-2.

Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & sourcing agent· Listing updated Sep 2026

Specifications

5SU1374-7DK82 — Electrical Ratings
ParameterValue
Number of poles4
Overvoltage categoryIII
5SU1374-7DK82 — Identification
ParameterValue
Product designationRCBO
5SU1374-7DK82 — Mechanical
ParameterValue
Mounting positionany
Width198 mm
Height90 mm
Depth77 mm
Installation depth70 mm
5SU1374-7DK82 — Environmental
ParameterValue
IP degree of protectionIP20, if the distribution board is installed, with connected conductors
5SU1374-7DK82 — Electrical
ParameterValue
Tripping Characteristic ClassC

Product details

The Siemens 5SU1374-7DK82 is a 4-pole RCBO from the SENTRON 5SU1 series, combining overcurrent protection and residual current detection in a single 11-module-wide unit. It is rated 125 A at 30 °C ambient, with a C tripping curve for moderate inrush loads like motor starters or transformer banks, and a Type B+ fault current characteristic that detects smooth DC residual currents up to 2 kHz — critical for variable-speed drives and UPS-fed circuits where standard AC/DC-sensitive RCDs may blind. Overvoltage category III means it is rated for fixed-installation distribution boards, not just downstream equipment.

Current derating and ambient limits

At 40 °C it derates to 115.62 A, at 45 °C to 111.25 A, at 50 °C to 106.25 A, at 55 °C to 101.25 A, and at 60 °C to 96.25 A.

Conductor sizing and termination

For a 125 A circuit, 35 mm² or 50 mm² copper is typical depending on installation method and ambient; the terminal range covers both without need for pin lugs.

Frequently asked questions

What is the breaking capacity of 5SU1374-7DK82?

10 kA per both EN 60898 and IEC 60947-2, which covers the majority of commercial and light industrial distribution boards.

What conductor sizes does 5SU1374-7DK82 accept?

Solid or stranded conductors from 6 mm² up to 50 mm², which covers the full range for a 125 A circuit.

What is the depth of 5SU1374-7DK82?

77 mm overall depth, with a 70 mm installation depth behind the panel face — fits standard 125 A rated enclosures.

Where can I buy 5SU1374-7DK82?

This part is sourced and quoted to order against an RFQ through independent distribution channels. Availability and current pricing are confirmed at quote time — submit an RFQ for a firm commitment.

MPN
5SU1374-7DK82