Siemens 5SU1424-1RC40 — Residual Current Breakers (RCCB/RCBO)

Siemens 5SU1424-1RC40 SENTRON RCBO 40A 2P C-Char 100mA AC Ty

MPN5SU1424-1RC40

Siemens SENTRON RCBO, 40 A, 2-pole, 4-module, C characteristic, Type AC, 100 mA residual current, 10/15 kA breaking capacity.

Sourced new & surplus through independent channelsAuthenticity-screened · ESD-safe packingListing updated Jul 2026

Specifications

5SU1424-1RC40 — Electrical Ratings
ParameterValue
Number of poles2
Overvoltage categoryIII
5SU1424-1RC40 — Identification
ParameterValue
Product designationRCBO
5SU1424-1RC40 — Mechanical
ParameterValue
Mounting positionany
Width in modular units4
Maximum75 °C
Minimum-40 °C
Width72 mm
Height90 mm
Depth70 mm
Installation depth70 mm
5SU1424-1RC40 — Environmental
ParameterValue
IP degree of protectionIP20, if the distribution board is installed, with connected conductors
5SU1424-1RC40 — Electrical
ParameterValue
Tripping Characteristic ClassC

Product details

It is designed for 50 Hz AC supply networks and carries a breaking capacity of 10 kA per EN 60898 and 15 kA per IEC 60947-2, giving it fault-clearing capability suitable for residential and light commercial distribution boards. Type AC detection responds to sinusoidal AC fault currents. For circuits with pulsating DC leakage, use Type A or Type F. 100 mA sensitivity suits circuits with expected equipment earth leakage. The C characteristic has a magnetic trip threshold of 5 to 10 times the rated current (200–400 A instantaneous trip for this 40 A unit), intended for circuits with moderate inrush — motor-starting, banks of fluorescent lighting, small transformers.

The 4-module width (72 mm) and 70 mm depth fit standard SENTRON distribution boards and enclosures. Supply can enter from either top or bottom. The IP20 rating applies with conductors connected inside an installed distribution board — not suitable for wet or dusty locations without an outer enclosure. Mounting position is unrestricted.

The EN 60898 value is the one used for coordination in residential and commercial final circuits per the standard's scope. The IEC 60947-2 rating applies when the device is deployed in an industrial context where the standard's more demanding performance criteria (including I²t let-through and operating sequence) are specified. For selectivity with an upstream SENTRON fuse or MCCB, the 15 kA figure provides additional headroom in the fault-current withstand calculation at the distribution board.

Frequently asked questions

Will 5SU1424-1RC40 drop into a panel specified around 5SL4363-7 without rewiring?

No. The 5SL4363-7 is a 3-pole miniature circuit breaker (MCB), not an RCBO. It occupies 3 modular width units (54 mm) versus the 4-module (72 mm) 5SU1424-1RC40. The RCBO also requires a neutral connection for the residual current detection circuit, which the MCB does not. Panel layout and wiring differ.

MPN