Skip to main content
Siemens 5SU1444-2RC63 — Residual Current Breakers (RCCB/RCBO)

Siemens 5SU1444-2RC63 SENTRON RCBO 63A 4P D-curve 100mA AC-t

MPN5SU1444-2RC63

Siemens SENTRON RCBO, 63 A, 4-pole, 7 MW, D characteristic, AC-type, 100 mA, 10 kA (EN 60898), 15 kA (IEC 60947-2), 70 mm depth, IP20.

Sourced new & surplus through independent channelsAuthenticity-screened · ESD-safe packingListing updated Aug 2026

Specifications

5SU1444-2RC63 — Electrical Ratings
ParameterValue
Number of poles4
Overvoltage categoryIII
5SU1444-2RC63 — Identification
ParameterValue
Product designationRCBO
5SU1444-2RC63 — Mechanical
ParameterValue
Mounting positionany
Width in modular units7
Maximum75 °C
Minimum-40 °C
Width126 mm
Height90 mm
Depth70 mm
Installation depth70 mm
5SU1444-2RC63 — Environmental
ParameterValue
IP degree of protectionIP20, if the distribution board is installed, with connected conductors
5SU1444-2RC63 — Electrical
ParameterValue
Tripping Characteristic ClassD

Product details

63 A RCBO with D-curve and AC-type residual current — what it means on the panel

The Siemens 5SU1444-2RC63 is a 4-pole RCBO (residual current breaker with overcurrent protection) from the SENTRON family, rated 63 A at 415 V AC, 50 Hz. It combines a D-curve MCB with an AC-type 100 mA residual current device in one 7-module-wide unit.

Mounting and integration — 7 MW footprint, any orientation

Occupies 7 modular width units (126 mm) on a DIN rail; depth is 70 mm. Mounting position is unrestricted — install upright, sideways, or inverted inside the distribution board. Supply can enter from top or bottom. The IP20 rating applies with the distribution board closed and conductors connected — standard for enclosed panel installation, not for exposed mounting. The 70 mm installation depth matches standard SENTRON RCBO dimensions; check your enclosure's door clearance if using a shallow box. Four poles protected (all poles switched and monitored for residual current). The 4-pole design covers three-phase-plus-neutral circuits; for single-phase or three-phase without neutral, a 1P+N or 3P variant would be the correct choice.

Frequently asked questions

How do I get current pricing and availability for 5SU1444-2RC63?

Submit an RFQ through the storefront. Availability and current pricing are confirmed at quote time through independent distribution channels.

What is 5SU1444-2RC63's listed depth?

70 mm installation depth, matching the standard SENTRON RCBO footprint.

Will 5SU1444-2RC63 drop into a panel specified around 5SU9354-7KK16?

No — the 5SU9354-7KK16 is a 1P+N 2-module RCD-operated circuit breaker, while the 5SU1444-2RC63 is a 4-pole 7-module RCBO. The width (126 mm vs 36 mm), pole count, and wiring differ completely; the panel would need rewiring and a larger DIN-rail allocation.

What compliance documentation is available for 5SU1444-2RC63?

The part carries ratings per EN 60898 and IEC 60947-2, overvoltage category III, pollution degree 2, and IP20 protection. Standard SENTRON documentation includes CE declaration of conformity; specific RoHS/REACH/UL status should be verified from the manufacturer's current compliance documents.

MPN
5SU1444-2RC63