Siemens 5SU1454-1KK06 — Residual Current Breakers (RCCB/RCBO)

Siemens SENTRON 5SU1454-1KK06 RCBO, 6 A, C curve, 100 mA, 10

MPN5SU1454-1KK06

Siemens SENTRON 5SU1454-1KK06 RCBO, 2-pole (1P+N), 6 A rated, C trip curve, 100 mA residual current, 10 kA breaking capacity, 50 Hz, IP20.

Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & sourcing agent· Listing updated Sep 2026

Specifications

5SU1454-1KK06 — Electrical Ratings
ParameterValue
Number of poles2
Overvoltage categoryIII
5SU1454-1KK06 — Identification
ParameterValue
Product designationRCBO
Product design / constructionInstantaneous
5SU1454-1KK06 — Mechanical
ParameterValue
Mounting positionany
Width in modular units2
Maximum75 °C
Minimum-40 °C
Width36 mm
Height90 mm
Depth77 mm
Installation depth70 mm
5SU1454-1KK06 — Environmental
ParameterValue
IP degree of protectionIP20, if the distribution board is installed, with connected conductors
5SU1454-1KK06 — Electrical
ParameterValue
Tripping Characteristic ClassC
Operational current / at AC / rated value6 A

Product details

The Siemens SENTRON 5SU1454-1KK06 is a 2-pole (1P+N) residual-current circuit breaker with overcurrent protection — an RCBO — combining a 6 A thermal-magnetic MCB (C curve) and a 100 mA AC-type RCD in one 36 mm wide, 2-module-width housing. It protects a single-phase final subcircuit against overload, short-circuit (10 kA Icn per EN 60898, 35 kA Icu per IEC 60947-2), and earth faults up to the rated residual current. The neutral pole is switched, so the outgoing neutral is disconnected when the device trips or is manually opened.

Its 36 mm width (2 module units) matches the standard SENTRON modular grid. Supply can enter from either top or bottom, which simplifies wiring when the busbar arrangement dictates the feed direction. The IP20 rating applies once installed with conductors connected — the panel enclosure provides the environmental seal.

The C-curve trip characteristic means the magnetic release operates at 5 to 10 times rated current (30–60 A for this 6 A unit), suited for circuits with moderate inrush — lighting banks, small motor loads, control transformers. The 100 mA residual-current sensitivity (AC type) detects sinusoidal earth faults only; it is not suitable for pulsating DC or smooth DC fault currents (those need type A or F). The 10 kA Icn rating covers the majority of domestic and light commercial service-entrance fault levels; the 35 kA Icu rating gives additional headroom for industrial panels with higher prospective short-circuit current — the device can interrupt a 35 kA fault once (Icu) and still be functional afterward, whereas Icn is the rated short-circuit capacity for the full duty cycle.

Frequently asked questions

What is the rated current and residual current of 5SU1454-1KK06?

The rated operational current is 6 A at 230/240 V AC, and the rated residual tripping current is 100 mA (AC type).

What is the breaking capacity of 5SU1454-1KK06?

The Icn (rated short-circuit capacity per EN 60898) is 10 kA; the Icu (ultimate breaking capacity per IEC 60947-2) is 35 kA.

Where can I buy 5SU1454-1KK06?

This part is sourced and quoted to order against an RFQ through independent distribution. Availability and current pricing are confirmed at quote time.

What is the physical size of 5SU1454-1KK06?

Width is 36 mm (2 module units), height is 90 mm, depth is 77 mm, and installation depth is 70 mm.