Siemens 5SU1454-1KK13 — Residual Current Breakers (RCCB/RCBO)

Siemens 5SU1454-1KK13 SENTRON RCBO, 13 A, 10 kA, Type C, 1P+

MPN5SU1454-1KK13

Siemens SENTRON 5SU1454-1KK13 RCBO, 2-pole (1P+N), Type C, 13 A at 30 °C, 10 kA per EN 60898, 20 kA per IEC 60947-2, 2 MW, halogen-free, IP20 with board installed.

Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & sourcing agent· Listing updated Sep 2026

Specifications

5SU1454-1KK13 — Electrical Ratings
ParameterValue
Number of poles2
Overvoltage categoryIII
5SU1454-1KK13 — Identification
ParameterValue
Product designationRCBO
Product design / constructionInstantaneous
5SU1454-1KK13 — Mechanical
ParameterValue
Mounting positionany
Width in modular units2
Maximum75 °C
Minimum-40 °C
Width36 mm
Height90 mm
Depth77 mm
Installation depth70 mm
5SU1454-1KK13 — Environmental
ParameterValue
IP degree of protectionIP20, if the distribution board is installed, with connected conductors
5SU1454-1KK13 — Electrical
ParameterValue
Tripping Characteristic ClassC
Operational current / at AC / rated value13 A

Product details

It combines a Type C miniature circuit breaker and a residual current device (Type AC) into one unit, protecting against both overload/short-circuit and earth leakage in a single 1P+N pole configuration. The breaking capacity is 10 kA per EN 60898 and 20 kA per IEC 60947-2, so it can interrupt fault currents up to 20 kA at 230/240 V AC without upstream cascading.

Temperature derating and installation

At 40 °C the continuous current drops to 12.48 A, at 55 °C to 11.57 A, and at 70 °C to 10.01 A. If the panel runs hot (e.g., enclosed with other heat-generating devices), use the derated figure for the BOM load calculation — the breaker will trip earlier than the nameplate suggests if the ambient exceeds 30 °C. IP20 is achieved only when the distribution board is installed with connected conductors — not a standalone rating.

Halogen-free and silicon-free construction. Rated for 50 Hz only. The function designation per IEC 81346-2 and DIN EN 61346-2 is F. Test equipment minimum voltage is 100 V AC.

Frequently asked questions

How do I get current pricing and availability for 5SU1454-1KK13?

The part is sourced and quoted to order against an RFQ through independent distribution. Availability and current pricing are confirmed at quote time — submit an RFQ for a firm quote.

What is 5SU1454-1KK13's listed depth?

The overall depth is 77 mm; the installation depth (behind the panel face) is 70 mm.

What compliance documentation does this RCBO provide?

It is halogen-free and silicon-free, rated for overvoltage category III, pollution degree 2, and energy limitation class 3. The breaking capacity is certified per EN 60898 (10 kA) and IEC 60947-2 (20 kA).