Siemens 5SU1624-6KK82 — Residual Current Breakers (RCCB/RCBO)

Siemens SENTRON 5SU1624-6KK82 RCBO, 125 A, 10 kA, Type A, 30

MPN5SU1624-6KK82
Active

Siemens SENTRON RCBO, 2-pole, B-curve, Type A, 300 mA, 125 A, 10 kA breaking capacity, 5SU1624-6KK82.

Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & sourcing agent· Listing updated Sep 2026

Specifications

5SU1624-6KK82 — Electrical Ratings
ParameterValue
Number of poles2
Overvoltage categoryIII
5SU1624-6KK82 — Identification
ParameterValue
Product designationRCBO
Product design / constructionInstantaneous
5SU1624-6KK82 — Mechanical
ParameterValue
Mounting positionany
Width in modular units7
Maximum75 °C
Minimum-40 °C
Height90 mm
Depth77 mm
Installation depth70 mm
5SU1624-6KK82 — Environmental
ParameterValue
IP degree of protectionIP20, if the distribution board is installed, with connected conductors
5SU1624-6KK82 — Electrical
ParameterValue
Tripping Characteristic ClassB

Product details

The Siemens SENTRON 5SU1624-6KK82 is a 2-pole RCBO (residual current circuit breaker with overcurrent protection) rated 125 A at 230/400 V AC, 50 Hz. It combines a Type A residual current device (300 mA sensitivity) with a B-curve miniature circuit breaker into a single 7-module-width unit. The 10 kA breaking capacity per EN 60898 and IEC 60947-2 means it can safely interrupt fault currents up to that level on a 230/400 V supply — enough for most residential and light commercial distribution boards where the prospective short-circuit current is known to stay under that threshold.

The Type A RCD detects pulsating DC residual currents in addition to sinusoidal AC, which covers modern electronics and single-phase rectified loads. At 125 A, this is a high-current RCBO; most panelboards will need a 125 A busbar tap or a dedicated feed. The 7 MW (modular width units) means it occupies 7 x 18 mm = 126 mm on the DIN rail — plan the enclosure layout accordingly; a standard 12-module consumer unit won't fit this alongside many other ways.

Mounting and environment

The IP20 rating applies only when installed in a distribution board with conductors connected — this is a panel-mount device, not for standalone outdoor use. Mounting position is any orientation. The supply can enter from either top or bottom, which simplifies wiring in tight enclosures. Installation depth is 70 mm (unit depth 77 mm including the front projection).

Compliance and approvals

Insulation voltage (Ui) is 440 V; surge voltage resistance is 4 kV. Overvoltage category III, pollution degree 2 — standard for fixed-installation distribution boards. Halogen-free and silicon-free construction.

Frequently asked questions

What is the breaking capacity of 5SU1624-6KK82?

10 kA per both EN 60898 and IEC 60947-2. That's the maximum fault current it can safely interrupt at 230/400 V AC.

What does B-curve mean on this RCBO?

B-curve trips at 3 to 5 times rated current (In = 125 A), so it's for resistive and general-purpose loads. Not ideal for motor starting or high-inrush loads.

Where can I buy 5SU1624-6KK82?

Sourced and quoted to order against an RFQ through independent distribution. Availability and current pricing are confirmed at quote time.

MPN
5SU1624-6KK82