Skip to main content
Siemens 5SU1644-1KK82 — Residual Current Breakers (RCCB/RCBO)

Siemens 5SU1644-1KK82 SENTRON RCBO, 125 A, 4-Pole, C-Curve,

MPN5SU1644-1KK82

Siemens SENTRON 5SU1644-1KK82, RCBO, 4-pole, 125 A (at 30 °C), C-curve, 300 mA residual current, 10 kA breaking capacity per EN 60898 and IEC 60947-2.

Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & sourcing agent· Listing updated Sep 2026

Specifications

5SU1644-1KK82 — Electrical Ratings
ParameterValue
Number of poles4
Overvoltage categoryIII
5SU1644-1KK82 — Identification
ParameterValue
Product designationRCBO
Product design / constructionInstantaneous
5SU1644-1KK82 — Mechanical
ParameterValue
Mounting positionany
Width in modular units11
Maximum75 °C
Minimum-40 °C
Installation depth70 mm
5SU1644-1KK82 — Environmental
ParameterValue
IP degree of protectionIP20, if the distribution board is installed, with connected conductors
5SU1644-1KK82 — Electrical
ParameterValue
Tripping Characteristic ClassC

Product details

The Siemens 5SU1644-1KK82 is a SENTRON RCBO — a combined residual-current circuit breaker with overcurrent protection — rated 125 A at 30 °C, 4-pole, C-curve trip characteristic, and 300 mA residual-current sensitivity. The C-curve means it holds through motor inrush up to about 5–10× rated current, then trips fast — sized for mixed resistive-inductive loads like pump circuits or compressor feeds.

Mounts on DIN rail, any position. At 11 modular width units (roughly 198 mm), it occupies a standard panel slot. Installation depth is 70 mm. IP20 with conductors connected and distribution board installed, so it lives inside a closed enclosure, not exposed to washdown.

Thermal derating is published: 125 A at 30 °C drops to 115.62 A at 40 °C, 111.25 A at 45 °C, 106.25 A at 50 °C, 101.25 A at 55 °C, and 96.25 A at 60 °C.

Frequently asked questions

What is 5SU1644-1KK82's maximum and minimum operating temperature?

Maximum ambient is 75 °C; minimum is -40 °C. The thermal derating curve applies above 30 °C.

Where can I buy 5SU1644-1KK82 and how is it quoted?

Sourced and quoted to order against an RFQ through independent distribution. Availability and current pricing are confirmed at quote time.

Will 5SU1644-1KK82 drop into a panel specified around 5SY4310-7CV without rewiring?

No — 5SY4310-7CV is a miniature circuit breaker (MCB) without residual-current protection. The 5SU1644-1KK82 is an RCBO that combines overcurrent and residual-current protection in one unit, so it requires the neutral conductor to pass through the device. Panel wiring differs.

What compliance documentation does Siemens provide for 5SU1644-1KK82?

The part carries EN 60898 and IEC 60947-2 ratings for breaking capacity, and is halogen-free and silicon-free. Full RoHS, REACH, and CE documentation is standard from Siemens for this SENTRON series.

MPN
5SU1644-1KK82