Siemens 5SU1653-0KV10 — Residual Current Breakers (RCCB/RCBO)

Siemens 5SU1653-0KV10 FI/LS Protector, Type AC 300mA, B 10A

MPN5SU1653-0KV10

Siemens 5SU1653-0KV10 FI/LS-PROTECTOR, Type AC (WS), D=70mm, IΔN 300mA, 4.5kA, 1+N-POL, B characteristic 10A.

StockContact for availability
MOQ1 pcs
Sourced new & surplus through independent channelsListing updated Jul 2026

Product details

Siemens 5SU1653-0KV10 — FI/LS Protector, Type AC, 300mA, B 10A

The Siemens 5SU1653-0KV10 is a combined residual-current device and miniature circuit breaker (RCBO) in a single 1+N-POL module, rated B 10A with a 300mA Type AC earth leakage trip. The 4.5kA short-circuit breaking capacity suits residential and light commercial distribution boards where fault levels stay under that threshold. The Type AC detection covers sinusoidal AC residual currents — the standard choice for general socket-outlet and lighting circuits where no rectified or smoothed DC fault currents are expected.

What the Ratings Mean for Fit

The B characteristic (10A rated current) trips instantaneously at 3–5× In (30–50A), sized for resistive and moderate inductive loads like lighting, socket circuits, and small appliances — not for motor-starting inrush. The 300mA residual sensitivity is a fire-protection level (not personal shock protection), used on circuits where 30mA nuisance tripping is unacceptable but earth-fault fire risk must be covered, such as fixed lighting or distribution sub-mains. The 4.5kA breaking capacity (IEC 60898) means it clears a short-circuit fault up to 4.5kA at the rated voltage without rupturing; verify the prospective short-circuit current (PSCC) at the installation point stays below this.

Panel Integration

The 1+N-POL module (switched line, switched neutral) snaps onto standard DIN rail in a distribution board. The 70mm depth (D=70mm) matches the Siemens 5SV series RCBO footprint, so it fits existing board layouts without extra enclosure depth. Neutral busbar connection is internal to the module — no separate neutral link required downstream.

Frequently asked questions

What is the 5SU1653-0KV10 used for?

It is a combined RCD/MCB (RCBO) rated B 10A with 300mA Type AC earth leakage protection, used in residential and light commercial distribution boards for socket circuits, lighting, and sub-mains where fire-protection-level residual current detection is required.

Where can I buy the 5SU1653-0KV10?

This part is sourced and quoted to order against an RFQ through independent distribution. Availability and current pricing are confirmed at quote time.

What does the Type AC rating mean on this RCBO?

Type AC detection responds to sinusoidal AC residual currents only — it is the standard choice for general circuits where no rectified DC fault currents are present. For circuits with electronic loads that may produce pulsed DC faults, a Type A device would be specified instead.