Skip to main content
Siemens 5SU1653-7KK25 — Residual Current Breakers (RCCB/RCBO)

Siemens 5SU1653-7KK25 SENTRON RCBO 2-pole 25 A type C 30 mA

MPN5SU1653-7KK25
Active

Siemens SENTRON RCBO, 2-pole 1P+N, 25 A rated, tripping characteristic C, residual current type A 30 mA, 4.5 kA per EN 60898 / 15 kA per IEC 60947-2, instantaneous design, halogen-free, silicon-free.

Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & sourcing agent· Listing updated Sep 2026

Specifications

5SU1653-7KK25 — Electrical Ratings
ParameterValue
Number of poles2
Overvoltage categoryIII
5SU1653-7KK25 — Identification
ParameterValue
Product designationRCBO
Product design / constructionInstantaneous
5SU1653-7KK25 — Mechanical
ParameterValue
Mounting positionany
Width in modular units2
Maximum75 °C
Minimum-40 °C
Width36 mm
Height90 mm
Depth77 mm
Installation depth70 mm
5SU1653-7KK25 — Environmental
ParameterValue
IP degree of protectionIP20, if the distribution board is installed, with connected conductors
5SU1653-7KK25 — Electrical
ParameterValue
Tripping Characteristic ClassC

Product details

RCBO for panel and machine protection

The Siemens 5SU1653-7KK25 is a 2-pole (1P+N) SENTRON RCBO combining overcurrent and residual current protection in a single 36 mm wide module (2 MW). The breaking capacity is 4.5 kA per EN 60898 and 15 kA per IEC 60947-2, giving the headroom to clear high fault currents in industrial distribution without upstream coordination issues.

The 5SU1653-7KK25 snaps onto a standard DIN rail and occupies 2 modular width units (36 mm), with an installation depth of 70 mm and overall depth of 77 mm.

Temperature derating

The rated current is 25 A at 30 °C, but derates progressively with ambient temperature: 23.5 A at 40 °C, 22.75 A at 45 °C, 21.75 A at 50 °C, 20.25 A at 55 °C and 60 °C, 19.25 A at 65 °C, and 18.25 A at 70 °C. For a panel running at 50 °C ambient — typical in a sealed enclosure with drives — the effective continuous current drops to 21.75 A, so the load must be sized accordingly.

Frequently asked questions

What is the closest functional second-source for 5SU1653-7KK25?

The peer 5SU9354-7KK16 is a similar SENTRON RCBO, but verify the residual current type and breaking capacity against your BOM — the 5SU1653-7KK25 uses type A residual current and a 4.5/15 kA breaking capacity.

Will 5SU1653-7KK25 drop into a panel specified around 5SU9354-7KK16 without rewiring?

Both are 2 MW (36 mm) DIN-rail modules with the same 1P+N pole configuration, so the physical fit is identical. Check the residual current type and breaking capacity to confirm electrical compatibility.

MPN
5SU1653-7KK25