Siemens 5SU1654-1KV06 — Residual Current Breakers (RCCB/RCBO)

Siemens 5SU1654-1KV06 FI/LS Protector, 6A C-curve, 300mA, 10

MPN5SU1654-1KV06

Siemens 5SU1654-1KV06 FI/LS protector, Type AC (WS), D=70mm, IΔn 300mA, 10kA, 1+N-pole, C-curve 6A.

StockContact for availability
MOQ1 pcs
Sourced new & surplus through independent channelsListing updated Jul 2026

Product details

The Siemens 5SU1654-1KV06 is an FI/LS combination unit — a combined residual-current device and miniature circuit breaker (RCBO) in a single 1+N-pole module. It carries a C-curve 6 A overcurrent trip and a 300 mA Type AC residual-current element, with a 10 kA breaking capacity. The D=70 mm dimension refers to the width of the enclosure, fitting standard Siemens distribution boards.

What the ratings mean for fit

The 6 A C-curve overcurrent element protects final circuits supplying resistive and light inductive loads — lighting, small appliances, control transformers — where inrush is moderate. The 300 mA Type AC residual-current element responds to sinusoidal AC fault currents only; it is not suitable for pulsating DC or smooth DC fault conditions (Type A or Type B would be required for drives, UPS, or EV charging circuits). The 10 kA breaking capacity at 230/400 V is adequate for most domestic and light commercial sub-distribution boards where the prospective short-circuit current at the point of installation is below 10 kA.

Deployment context

The 70 mm wide module snaps onto DIN rail inside a Siemens distribution board or similar enclosure. The Type AC residual element means it is intended for general-purpose AC circuits where no electronic loads generate non-sinusoidal fault currents. Common applications include lighting circuits, socket outlets in offices or residential buildings, and small motor circuits with contactor control.

Frequently asked questions

What is the breaking capacity of 5SU1654-1KV06?

The breaking capacity is 10 kA, suitable for sub-distribution boards with a prospective short-circuit current at or below that level.

What does the Type AC residual-current designation mean?

Type AC means the device detects sinusoidal AC residual currents only. It is not rated for pulsating DC or smooth DC fault currents — for those, a Type A or Type B device would be required.

Where can I buy 5SU1654-1KV06?

This part is sourced and quoted to order against an RFQ through independent distribution. Availability and current pricing are confirmed at quote time.