Skip to main content
Siemens 5SU1654-7KK20 — Residual Current Breakers (RCCB/RCBO)

Siemens 5SU1654-7KK20 SENTRON RCBO, 20 A, 300 mA, Type A, C-

MPN5SU1654-7KK20
Active

Siemens SENTRON RCBO, 2-pole 1P+N, 20 A, 300 mA, Type A, C-curve, 10 kA / 20 kA, 230/240 V AC, 50 Hz, 2 MW, IP20.

Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & sourcing agent· Listing updated Sep 2026

Specifications

5SU1654-7KK20 — Electrical Ratings
ParameterValue
Number of poles2
Overvoltage categoryIII
5SU1654-7KK20 — Identification
ParameterValue
Product designationRCBO
Product design / constructionInstantaneous
5SU1654-7KK20 — Mechanical
ParameterValue
Mounting positionany
Width in modular units2
Maximum75 °C
Minimum-40 °C
Width36 mm
Height90 mm
Depth77 mm
Installation depth70 mm
5SU1654-7KK20 — Environmental
ParameterValue
IP degree of protectionIP20, if the distribution board is installed, with connected conductors
5SU1654-7KK20 — Electrical
ParameterValue
Tripping Characteristic ClassC
Operational current / at AC / rated value20 A

Product details

It protects a single-phase final circuit against overload, short-circuit, and earth leakage, all in one DIN-rail unit.

The 20 kA figure gives headroom for industrial panel applications where fault currents may exceed 10 kA; the 10 kA rating covers the domestic/commercial coordination requirement.

Two modules wide (36 mm), 77 mm deep, 90 mm tall. Neutral conductor is switched internally (1P+N configuration), so no separate neutral bar is needed downstream. Supply can enter from top or bottom — no mandatory orientation. Touch-protected terminals reduce the risk of accidental contact during wiring. IP20 rating applies once installed in a distribution board with conductors connected; the device itself is not rated for wet or dusty environments.

Frequently asked questions

What is the breaking capacity of the 5SU1654-7KK20?

10 kA per EN 60898 and 20 kA per IEC 60947-2. The higher IEC figure applies in industrial installations where the prospective fault current exceeds 10 kA.

What is the residual current rating and type?

300 mA, Type A (sensitive to pulsating DC as well as AC sinusoidal residual currents). Suitable for circuits with electronic loads like rectifiers or switching power supplies.

Will the 5SU1654-7KK20 fit a panel designed for the 5SL6550-7BB?

Not without checking. Both are 2-module-wide DIN-rail RCBOs, but the 5SL6550-7BB is a different series with different breaking capacity and curve options. Verify the panel's required SCCR, residual sensitivity, and curve before substituting.

Where can I buy the 5SU1654-7KK20?

Sourced and quoted to order against an RFQ through independent distribution. Availability and current pricing are confirmed at quote time — no stock figures or lead-time numbers are published here.

MPN