Siemens 5SU1654-7KK40 — Residual Current Breakers (RCCB/RCBO)

Siemens 5SU1654-7KK40 SENTRON RCBO, 40 A, 10 kA, Type A, 300

MPN5SU1654-7KK40
Active

Siemens SENTRON 5SU1654-7KK40 RCBO, 1P+N, type A, 300 mA, C-characteristic, In: 40 A, Un AC: 230 V, 10 kA (EN 60898), 15 kA (IEC 60947-2), 50 Hz.

Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & sourcing agent· Listing updated Sep 2026

Specifications

5SU1654-7KK40 — Electrical Ratings
ParameterValue
Number of poles2
Overvoltage categoryIII
5SU1654-7KK40 — Identification
ParameterValue
Product designationRCBO
Product design / constructionInstantaneous
5SU1654-7KK40 — Mechanical
ParameterValue
Mounting positionany
Width in modular units2
Maximum75 °C
Minimum-40 °C
Width36 mm
Height90 mm
Depth77 mm
Installation depth70 mm
5SU1654-7KK40 — Environmental
ParameterValue
IP degree of protectionIP20, if the distribution board is installed, with connected conductors
5SU1654-7KK40 — Electrical
ParameterValue
Tripping Characteristic ClassC

Product details

Siemens SENTRON 5SU1654-7KK40 — RCBO, 40 A, Type A, 300 mA

The Siemens SENTRON 5SU1654-7KK40 is a 1P+N RCBO (residual current operated circuit breaker with overcurrent protection) rated 40 A at 230/240 V AC, 50 Hz, with a C tripping characteristic and Type A residual current sensitivity at 300 mA. Type A residual current detection handles pulsating DC fault currents — common on single-phase rectified loads (SMPS, LED drivers, VFD front-ends) — which a standard AC type would miss. IP20 applies once installed with conductors connected — the board enclosure provides the actual ingress protection.

Panel fit and mechanical data

Comparison with 5SU9354-7KK16

The closest functional peer is the 5SU9354-7KK16, also a 1P+N SENTRON RCBO with the same mechanical footprint (36×90×77 mm), same C-curve, and same halogen-free/silicon-free construction. The deciding difference: the 5SU1654-7KK40 carries a 15 kA breaking capacity per IEC 60947-2 versus 10 kA on the 5SU9354-7KK16, and its Type A residual current threshold is 300 mA (not 30 mA). The 5SU1654-7KK40 also has a lower minimum test voltage (100 V vs 195 V). If your coordination study requires 15 kA at the device or a 300 mA trip threshold, the 5SU1654-7KK40 is the correct BOM line; otherwise the 5SU9354-7KK16 is a drop-in alternative on the same panel cutout.

Frequently asked questions

What is the breaking capacity of 5SU1654-7KK40?

10 kA per EN 60898 and 15 kA per IEC 60947-2. The higher IEC rating gives headroom for industrial coordination studies where the device must clear faults up to 15 kA without upstream breaker intervention.

Will 5SU1654-7KK40 drop into a panel specified around 5SU9354-7KK16?

Yes — both share the same 36×90×77 mm footprint, 2 MW width, DIN-rail mounting, and 1P+N pole configuration. The 5SU1654-7KK40 has a higher IEC breaking capacity (15 kA vs 10 kA) and a 300 mA (not 30 mA) residual threshold, so verify the coordination study and RCD sensitivity requirements before swapping.

Where can I buy 5SU1654-7KK40?

Sourced and quoted to order against an RFQ through independent distribution. Availability and current pricing are confirmed at quote time.