Siemens 5SU1656-6KK10 — Residual Current Breakers (RCCB/RCBO)

SENTRON 5SU1656-6KK10 RCBO, 2-pole, 10 A, Type A, 6 kA

MPN5SU1656-6KK10
Active

SENTRON 5SU1656-6KK10, RCBO, 2-pole, 10 A, B-curve, Type A residual current, 6 kA (EN 60898) / 15 kA (IEC 60947-2), 2 MW, halogen-free.

$106.35Ref. price · indicative, final on quote
Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & sourcing agent· Listing updated Sep 2026

Specifications

5SU1656-6KK10 — Electrical Ratings
ParameterValue
Number of poles2
Overvoltage categoryIII
5SU1656-6KK10 — Identification
ParameterValue
Product designationRCBO
Product design / constructionInstantaneous
5SU1656-6KK10 — Mechanical
ParameterValue
Mounting positionany
Width in modular units2
Maximum75 °C
Minimum-40 °C
Width36 mm
Height90 mm
Depth77 mm
Installation depth70 mm
5SU1656-6KK10 — Environmental
ParameterValue
IP degree of protectionIP20, if the distribution board is installed, with connected conductors
5SU1656-6KK10 — Electrical
ParameterValue
Tripping Characteristic ClassB

Product details

The 6 kA EN rating covers the residential and light commercial install base.

Derating and mounting — what the numbers actually mean for a panel build

At 30 °C ambient the device carries its full 10 A. But as the panel warms up — and it will, with other breakers and contactors sharing the enclosure — the rated current drops steadily: 9.5 A at 40 °C, 9 A at 50 °C, 8.5 A at 60 °C, and 8 A at 70 °C. If you're populating a densely packed consumer unit or a small distribution board, you need to check the actual ambient temperature at the breaker's location, not the room temperature. A 10 A circuit loaded to 9 A continuous in a 50 °C panel is already at its limit — no headroom for a startup surge. The installation depth is 70 mm (body depth 77 mm including the front projection), so it fits standard 80 mm deep distribution boards. IP20 is the rating, but that's only valid when the distribution board is installed and the conductors are connected — the front face is touch-protected (finger-safe), but the terminals aren't sealed against dust ingress until the board cover is on.

Frequently asked questions

What are the key ratings I need to check for fit?

10 A rated current, B-curve trip characteristic, Type A residual current, 6 kA (EN 60898) / 15 kA (IEC 60947-2) breaking capacity, 2-pole, 36 mm wide (2 MW). Derate per the ambient temperature table if the panel runs hot.

Will the 5SU1656-6KK10 drop into a panel designed for the 5SL4363-7?

No — the 5SL4363-7 is a different class of device (a miniature circuit breaker only, no residual current element). The 5SU1656-6KK10 is an RCBO, so it's deeper (77 mm vs the MCB's typical 70 mm) and requires a neutral connection for the residual current electronics. The 36 mm width (2 MW) is the same, but the wiring and the space behind the DIN rail need to accommodate the extra depth and the neutral tail.

What compliance documentation is available for this part?

The device is halogen-free and silicon-free, rated for overvoltage category III and pollution degree 2. It carries EN 60898 and IEC 60947-2 ratings. The manufacturer provides the usual CE declaration, RoHS and REACH compliance statements with the product documentation.