Siemens 5SU1656-6KK13 SENTRON RCBO, 13 A, Type A, Char B, 6

MPN5SU1656-6KK13
Active

Siemens SENTRON RCBO, 13 A, Type A, B-curve, 2-pole 1P+N, 6 kA (EN 60898) / 15 kA (IEC 60947-2), 2 MW, IP20, halogen-free, silicon-free.

Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & sourcing agent· Listing updated Sep 2026

Specifications

5SU1656-6KK13 — Electrical Ratings
ParameterValue
Number of poles2
Overvoltage categoryIII
5SU1656-6KK13 — Identification
ParameterValue
Product designationRCBO
Product design / constructionInstantaneous
5SU1656-6KK13 — Mechanical
ParameterValue
Mounting positionany
Width in modular units2
Maximum75 °C
Minimum-40 °C
Width36 mm
Height90 mm
Depth77 mm
Installation depth70 mm
5SU1656-6KK13 — Environmental
ParameterValue
IP degree of protectionIP20, if the distribution board is installed, with connected conductors
5SU1656-6KK13 — Electrical
ParameterValue
Tripping Characteristic ClassB

Product details

The Siemens 5SU1656-6KK13 is a SENTRON RCBO (residual current circuit breaker with overcurrent protection) rated 13 A at AC, with a Type A residual current sensitivity and a B-curve instantaneous trip characteristic. It occupies 2 modular width units (36 mm) on a DIN rail and is rated for 6 kA breaking capacity per EN 60898 and 15 kA per IEC 60947-2, giving it a solid fault-clearing margin for most residential and light commercial panelboards.

Mounts in any position on a DIN rail with an installation depth of 70 mm and a total depth of 77 mm. The 1P+N configuration (switched phase, solid neutral) fits standard single-phase final circuits. Supply can enter from either top or bottom, which simplifies panel wiring when busbar routing is tight. IP20 rating applies when installed in a distribution board with connected conductors — standard for enclosed panel use, not for wet or outdoor locations without an additional enclosure.

Temperature derating is published for this unit: at 40 °C ambient the rated current drops to 12.48 A, at 50 °C to 11.96 A, and at 70 °C to 10.01 A. If the panel runs hot — near a transformer or in a non-ventilated enclosure — size the circuit load against the derated figure, not the 13 A nameplate.

Halogen-free and silicon-free construction matters for environments sensitive to outgassing — clean rooms, food processing, or areas with sensitive contacts. The part carries pollution degree 2 and overvoltage category III ratings, suitable for fixed-installation final circuits.

Frequently asked questions

Where can I buy 5SU1656-6KK13 and how do I get a price?

This part is sourced and quoted to order against an RFQ through independent distribution. Availability and current pricing are confirmed at quote time.

What is 5SU1656-6KK13's listed depth?

The total depth is 77 mm, with an installation depth of 70 mm.

What is 5SU1656-6KK13's width?

Width is 36 mm, which corresponds to 2 modular width units on a DIN rail.

What compliance documentation does Siemens provide for 5SU1656-6KK13?

The part is halogen-free and silicon-free, rated to pollution degree 2 and overvoltage category III, and carries breaking capacity ratings per EN 60898 (6 kA) and IEC 60947-2 (15 kA).