Siemens 5SU1656-6KV10 — Residual Current Breakers (RCCB/RCBO)

Siemens 5SU1656-6KV10 FI/LS Protector, Type A, 10A B-Curve,

MPN5SU1656-6KV10

Siemens 5SU1656-6KV10 FI/LS protector, Type A (PSE/SSF), 70mm, 300mA, 6kA, 1+N-pole, B-curve 10A.

StockContact for availability
MOQ1 pcs
Sourced new & surplus through independent channelsListing updated Jul 2026

Product details

The Siemens 5SU1656-6KV10 is an FI/LS protector (RCBO) combining residual current and overcurrent protection in a single 1+N-pole module. Type A sensitivity detects pulsating DC fault currents up to 300 mA, while the B-curve 10 A thermal-magnetic trip handles short-circuit and overload. The 6 kA breaking capacity at 230/400 V is sized for final subcircuits in residential and light commercial distribution boards — not for main switchboard fault levels.

What the Ratings Mean

The 300 mA residual rating is the threshold for Type A earth-leakage detection — it will trip on sinusoidal AC faults and on pulsating DC faults (typical of half-wave rectified loads like switching power supplies or LED drivers). The B-curve 10 A overcurrent element trips at 3 to 5 times rated current (30-50 A), which is the standard characteristic for resistive and general-purpose loads; it is not intended for motor-starting inrush (use C or D curve for that). The 6 kA breaking capacity is the maximum prospective fault current the device can safely interrupt — adequate for most final circuits downstream of a distribution board with a higher-rated upstream breaker.

Deployment Context

The 70 mm width (4 module spaces) snaps onto standard DIN rail in a consumer unit or sub-distribution board. The 1+N-pole configuration switches the line conductor only; the neutral is switched internally for isolation but not protected against overcurrent. This is the typical arrangement for single-phase final circuits where the neutral is solidly bonded upstream.

Frequently asked questions

Where can I buy 5SU1656-6KV10 and get a price?

This part is sourced to order against an RFQ through independent distribution channels. Submit an RFQ for current availability and pricing — confirmed at quote time, not before.

What is the breaking capacity of 5SU1656-6KV10?

The FI/LS protector is rated for 6 kA breaking capacity at 230/400 V, which covers final subcircuit fault levels in most residential and light commercial installations.

What does Type A residual current detection mean?

Type A detects both sinusoidal AC earth faults and pulsating DC fault currents (e.g., from half-wave rectified loads). The 300 mA sensitivity is the trip threshold for both waveforms.