Siemens 5SU1656-7KK16 — Residual Current Breakers (RCCB/RCBO)

Siemens 5SU1656-7KK16 SENTRON RCBO, 16 A C-curve, 6 kA

MPN5SU1656-7KK16
Active

Siemens SENTRON 5SU1656-7KK16 RCBO, 1P+N, 16 A at 30 °C, C-curve, 6 kA (EN 60898), 15 kA (IEC 60947-2), 2 MW, halogen-free.

$114.26Ref. price · indicative, final on quote
Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & sourcing agent· Listing updated Sep 2026

Specifications

5SU1656-7KK16 — Electrical Ratings
ParameterValue
Number of poles2
Overvoltage categoryIII
5SU1656-7KK16 — Identification
ParameterValue
Product designationRCBO
Product design / constructionInstantaneous
5SU1656-7KK16 — Mechanical
ParameterValue
Mounting positionany
Width in modular units2
Maximum75 °C
Minimum-40 °C
Width36 mm
Height90 mm
Depth77 mm
Installation depth70 mm
5SU1656-7KK16 — Environmental
ParameterValue
IP degree of protectionIP20, if the distribution board is installed, with connected conductors
5SU1656-7KK16 — Electrical
ParameterValue
Tripping Characteristic ClassC

Product details

The Siemens 5SU1656-7KK16 is a SENTRON RCBO — a combined residual-current device and miniature circuit breaker in a 1P+N, 2-pole package. Rated 16 A at 30 °C with a C tripping curve, it handles overcurrents and earth faults in a single 36 mm wide module. The interrupting capacity is 6 kA per EN 60898 and 15 kA per IEC 60947-2, giving it a solid safety margin for residential and light commercial distribution boards.

The 16 A rating holds at 30 °C ambient; above that, the current must be derated stepwise: 15.2 A at 40 °C, 14.4 A at 50 °C, 13.6 A at 60 °C, and 12.32 A at 70 °C. The device is 36 mm wide (2 modular width units), 77 mm deep, with an installation depth of 70 mm, and can be mounted in any position.

Halogen-free and silicon-free construction, which reduces toxic gas emission in a fire and avoids silicone contamination in sensitive environments like clean rooms or coating lines. The insulation voltage is rated 264 V, surge voltage resistance 4 000 V.

Frequently asked questions

What is the closest functional second-source to 5SU1656-7KK16?

The 5SL4363-7 is a different series — it is an MCB only, not an RCBO. The 5SU1656-7KK16 combines overcurrent and residual-current protection in one unit, so substituting a 5SL would require adding a separate RCD and rewiring the protection scheme.

Will 5SU1656-7KK16 drop into a panel specified around 5SL4363-7?

No — the 5SL4363-7 is an MCB without residual-current protection. The 5SU1656-7KK16 is an RCBO, so it requires a neutral connection and occupies the same 36 mm width, but the protection scheme differs. You would need to re-evaluate the RCD coordination.