Siemens 5SU1656-7KK25 — Residual Current Breakers (RCCB/RCBO)

Siemens 5SU1656-7KK25 SENTRON RCBO, 25A, 300mA, Type A, 6kA

MPN5SU1656-7KK25
Active

Siemens SENTRON RCBO, 1P+N, 25 A, 300 mA, Type A, C-curve, 6 kA, 2 MW, IP20.

StockContact for availability
MOQ1 pcs
Sourced new & surplus through independent channelsListing updated Jul 2026

Specifications

Electrical Ratings

5SU1656-7KK25 — Electrical Ratings
ParameterValue
Number of poles2
Overvoltage categoryIII

Identification

5SU1656-7KK25 — Identification
ParameterValue
Product designationRCBO
Product design / constructionInstantaneous

Mechanical

5SU1656-7KK25 — Mechanical
ParameterValue
Mounting positionany
Width in modular units2
Maximum75 °C
Minimum-40 °C
Width36 mm
Height90 mm
Depth77 mm
Installation depth70 mm

Environmental

5SU1656-7KK25 — Environmental
ParameterValue
IP degree of protectionIP20, if the distribution board is installed, with connected conductors

Electrical

5SU1656-7KK25 — Electrical
ParameterValue
Tripping Characteristic ClassC

Product details

The Siemens 5SU1656-7KK25 is a SENTRON-series RCBO (residual current circuit breaker with overcurrent protection) combining a 25 A overcurrent trip (C-curve, 1P+N) with a 300 mA Type A residual current device in a single 2-module-width package. It is rated for 6 kA breaking capacity per EN 60898, making it suitable for final subcircuit protection in residential and commercial distribution boards where both overcurrent and earth-fault protection are required in one device.

Ratings and what they mean for fit

The 25 A rating at 30 °C is the headline thermal current; at elevated panel temperatures the device derates — 23.5 A at 40 °C, 21.75 A at 50 °C, and 18.25 A at 70 °C. If the distribution board sits in a warm environment (e.g., adjacent to a boiler or in a non-climate-controlled enclosure), use the 40 °C or 50 °C column for sizing, not the 30 °C figure. The 300 mA residual current rating and Type A classification mean the device detects sinusoidal AC fault currents and pulsating DC fault currents (common from rectified loads like switching power supplies, LED drivers, and variable-speed drives). It is not suitable for smooth DC fault currents — that would require Type B. For general-purpose final circuits with electronic loads, Type A is the standard choice. The C-curve (tripping characteristic class C) means the magnetic trip operates at 5 to 10 times rated current, so it handles moderate inrush from motorized loads (pumps, fans, compressors) without nuisance tripping, while still providing short-circuit protection. The 6 kA breaking capacity (per EN 60898) is adequate for most domestic and light commercial installations where the prospective short-circuit current at the board is under 6 kA.

Integration and mounting

The device occupies 2 modular width units (36 mm) on a DIN rail, with a depth of 77 mm and installation depth of 70 mm. It mounts in any position and accepts supply from either top or bottom. The IP20 rating applies when installed in a distribution board with connected conductors — meaning the board enclosure provides the environmental seal; the RCBO itself is finger-safe but not splash-proof.

Frequently asked questions

What is 5SU1656-7KK25's listed depth?

The depth is 77 mm, with an installation depth of 70 mm.

What is 5SU1656-7KK25's listed width?

The width is 36 mm, which corresponds to 2 modular width units.

MPN
5SU1656-7KK25