Skip to main content
Siemens 5SU1674-7AK82 — Residual Current Breakers (RCCB/RCBO)

Siemens 5SU1674-7AK82 SENTRON RCBO, 125A 4P C-curve 300mA Ty

MPN5SU1674-7AK82
Active

Siemens SENTRON 5SU1674-7AK82 RCBO, 4-pole, 125 A, C-curve, 300 mA Type B residual current, 10 kA breaking capacity (EN 60898 / IEC 60947-2).

Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & sourcing agent· Listing updated Sep 2026

Specifications

5SU1674-7AK82 — Electrical Ratings
ParameterValue
Number of poles4
Overvoltage categoryIII
5SU1674-7AK82 — Identification
ParameterValue
Product designationRCBO
Product design / constructionSuper resistant K
5SU1674-7AK82 — Mechanical
ParameterValue
Mounting positionany
Width in modular units11
Maximum75 °C
Minimum-40 °C
Width198 mm
Height90 mm
Depth77 mm
Installation depth70 mm
5SU1674-7AK82 — Environmental
ParameterValue
IP degree of protectionIP20, if the distribution board is installed, with connected conductors
5SU1674-7AK82 — Electrical
ParameterValue
Tripping Characteristic ClassC

Product details

The Siemens 5SU1674-7AK82 is a SENTRON RCBO combining overcurrent protection and residual current detection in a single 4-pole device. Rated 125 A at 30 °C with a C-curve tripping characteristic and 300 mA Type B residual current sensitivity, it handles sinusoidal AC, pulsating DC, and smooth DC fault currents — the Type B rating is what you need for VFD, UPS, or EV charging circuits where pure DC leakage can blind a standard RCD. Breaking capacity is 10 kA per both EN 60898 and IEC 60947-2, so it clears line-to-neutral and line-to-earth faults up to that level without upstream cascading. The 4-pole design (4P) protects all live conductors; the neutral pole is switched and monitored.

Temperature derating and panel fit

At 40 °C it derates to 115.62 A, at 45 °C to 111.25 A, at 50 °C to 106.25 A, at 55 °C to 101.25 A, and at 60 °C to 96.25 A. The unit occupies 11 modular width units (198 mm wide) with a depth of 77 mm and an installation depth of 70 mm. IP20 rating applies once the distribution board is installed with connected conductors — this is a panel-internal device, not a weather-exposed one.

Frequently asked questions

What is the breaking capacity of 5SU1674-7AK82?

10 kA per both EN 60898 and IEC 60947-2, covering line-to-neutral and line-to-earth faults.

What does Type B residual current mean on this RCBO?

Type B detects sinusoidal AC, pulsating DC, and smooth DC fault currents — required for circuits with VFDs, UPS systems, or EV chargers that can produce pure DC leakage.

What is the temperature derating for 5SU1674-7AK82?

Rated 125 A at 30 °C; derates to 115.62 A at 40 °C, 111.25 A at 45 °C, 106.25 A at 50 °C, 101.25 A at 55 °C, and 96.25 A at 60 °C.

Where can I buy 5SU1674-7AK82?

Sourced and quoted to order against an RFQ through independent distribution. Availability and current pricing are confirmed at quote time.

MPN
5SU1674-7AK82