Skip to main content
Siemens 5SU1674-8AK81 — Residual Current Breakers (RCCB/RCBO)

Siemens 5SU1674-8AK81 SENTRON RCBO, Type B, 100 A, 300 mA, 1

MPN5SU1674-8AK81
Active

Siemens SENTRON RCBO, 5SU1674-8AK81, Super Resistant K design, 4-pole, 100 A rated, Type B, 300 mA residual, D tripping characteristic, 10 kA breaking capacity.

Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & sourcing agent· Listing updated Sep 2026

Specifications

5SU1674-8AK81 — Electrical Ratings
ParameterValue
Number of poles4
Overvoltage categoryIII
5SU1674-8AK81 — Identification
ParameterValue
Product designationRCBO
Product design / constructionSuper resistant K
5SU1674-8AK81 — Mechanical
ParameterValue
Mounting positionany
Width in modular units11
Maximum75 °C
Minimum-40 °C
Width198 mm
Height90 mm
Depth77 mm
Installation depth70 mm
5SU1674-8AK81 — Environmental
ParameterValue
IP degree of protectionIP20, if the distribution board is installed, with connected conductors
5SU1674-8AK81 — Electrical
ParameterValue
Tripping Characteristic ClassD

Product details

Rated at 100 A (at 30 °C ambient) with a 300 mA residual fault current threshold, it provides both earth leakage and short-circuit/overload protection in a single modular device — a space-saving choice for distribution boards where separate RCCB and MCB would consume more width.

Type B residual current and D-curve overcurrent — what they mean for the installation

Type B residual current detection covers smooth DC, pulsating DC, and AC residual currents — essential where variable-frequency drives, UPS systems, or rectifier loads are downstream, since those can generate DC fault currents that Type A or AC devices cannot detect. Temperature derating is published: 100 A at 30 °C, 92.5 A at 40 °C, 89 A at 45 °C, 85 A at 50 °C, 81 A at 55 °C, and 77 A at 60 °C — the panel designer must apply these when the RCBO is enclosed or in a warm environment.

Width is 198 mm (11 modular width units), depth 77 mm, height 90 mm, with an installation depth of 70 mm — it occupies a standard DIN-rail footprint but at 11 MW is wider than a typical 4-pole MCB (usually 4 MW), so verify available rail space before panel layout. Mounting position is any; supply can enter from top or bottom, which simplifies busbar and cable routing in crowded enclosures. IP20 rating applies when installed in a distribution board with connected conductors — the RCBO itself is not sealed for wet or dusty environments; it belongs inside a panel.

Frequently asked questions

What does Type B residual current detection mean for my installation?

It detects smooth DC, pulsating DC, and AC residual currents — required when downstream loads include VFDs, UPS systems, or rectifiers that can generate DC fault currents.

MPN
5SU1674-8AK81