Siemens 5SU9104-1KK25 — Residual Current Breakers (RCCB/RCBO)

Siemens 5SU9104-1KK25 SENTRON RCD Circuit Breaker, 25 A, 10

MPN5SU9104-1KK25

Siemens SENTRON 5SU9104-1KK25, RCD-operated circuit breaker, 25 A rated at 30 °C, C-curve, 10 kA breaking capacity per EN 60898, 1P+N, 18 mm width, 77 mm depth.

Sourced new & surplus through independent channelsAuthenticity-screened · ESD-safe packingListing updated Aug 2026

Specifications

5SU9104-1KK25 — Electrical Ratings
ParameterValue
Number of poles2
Overvoltage categoryIII
5SU9104-1KK25 — Identification
ParameterValue
Product designationRCD-operated circuit breaker
Product design / constructionInstantaneous
5SU9104-1KK25 — Mechanical
ParameterValue
Mounting positionany
Maximum0.75 W
Width18 mm
Height125 mm
Depth77 mm
Installation depth70 mm
5SU9104-1KK25 — Environmental
ParameterValue
IP degree of protectionIP20, if the distribution board is installed, with connected conductors
5SU9104-1KK25 — Electrical
ParameterValue
Tripping Characteristic ClassC

Product details

Siemens SENTRON 5SU9104-1KK25 — RCD-operated circuit breaker, 25 A, C-curve, 10 kA

The Siemens 5SU9104-1KK25 is a 1P+N RCD-operated circuit breaker from the SENTRON 5SU9 series, combining overcurrent and residual current protection in a single 18 mm wide unit. Rated 25 A at 30 °C with a C tripping characteristic, it clears faults up to 10 kA per EN 60898 and IEC 60947-2. The instantaneous design means no intentional time delay on the RCD element — it trips on residual AC fault currents immediately. Rated current derates with ambient temperature: 23.5 A at 40 °C, 22.75 A at 45 °C, 21.75 A at 50 °C, and 20.25 A at 55 °C. For a panel running at 40 °C ambient, the effective continuous load limit is 23.5 A — not the 25 A nameplate. Plan your branch circuit load accordingly. The 18 mm width (one width unit) fits standard DIN-rail enclosures. Depth is 77 mm, installation depth 70 mm. Halogen-free and silicon-free construction, with touch protection on the terminals. Energy limiting class 3. Overvoltage category III. Ambient operating range -25 to +45 °C; storage range -40 to +75 °C.

Frequently asked questions

What is the breaking capacity of 5SU9104-1KK25?

The breaking capacity is 10 kA rated per EN 60898 and also 10 kA per IEC 60947-2. This means it can safely interrupt fault currents up to 10,000 A at the rated voltage.

What conductor sizes does 5SU9104-1KK25 accept?

Solid conductors from 0.75 mm² to 35 mm², and stranded conductors from 0.75 mm² to 35 mm². This covers common panel wiring from control circuits up to main feeder taps.

What is the tripping characteristic and fault type?

The overcurrent trip is C-curve (magnetic trip between 5 and 10 times In). The residual current element is type AC, meaning it detects sinusoidal AC fault currents only — no pulsed DC or smooth DC detection.

Where can I buy 5SU9104-1KK25 and how is it quoted?

The part is sourced to order through our independent distribution channel. Submit an RFQ for current pricing and availability — confirmed at quote time, not before.

MPN
5SU9104-1KK25