Siemens 5SU9104-1KK40 — Residual Current Breakers (RCCB/RCBO)

Siemens 5SU9104-1KK40 SENTRON RCBO, 40 A, 10 kA, Type AC, 1P

MPN5SU9104-1KK40

Siemens SENTRON 5SU9104-1KK40, RCBO, 40 A, 10 kA, C-curve, 1P+N, Type AC, 18 mm wide.

Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & sourcing agent· Listing updated Sep 2026

Specifications

5SU9104-1KK40 — Electrical Ratings
ParameterValue
Number of poles2
Overvoltage categoryIII
5SU9104-1KK40 — Identification
ParameterValue
Product designationRCD-operated circuit breaker
Product design / constructionInstantaneous
5SU9104-1KK40 — Mechanical
ParameterValue
Mounting positionany
Maximum0.75 W
Width18 mm
Height125 mm
Depth77 mm
Installation depth70 mm
5SU9104-1KK40 — Environmental
ParameterValue
IP degree of protectionIP20, if the distribution board is installed, with connected conductors
5SU9104-1KK40 — Electrical
ParameterValue
Tripping Characteristic ClassC

Product details

The Siemens 5SU9104-1KK40 is a SENTRON RCBO — a combined RCD and MCB in one 18 mm-wide module, rated 40 A with a C tripping curve and 10 kA breaking capacity per EN 60898 and IEC 60947-2. It protects a single-phase final subcircuit (1P+N) against overload, short-circuit, and earth leakage, sensing AC fault currents only. The 18 mm width (1 MW) means it slots into a standard DIN-rail distribution board without crowding adjacent ways.

The 40 A rating is the continuous current at 30 °C ambient; at 40 °C it derates to 37.6 A, at 45 °C to 36.4 A, at 50 °C to 34.8 A, and at 55 °C to 32.4 A (–). The C-curve means magnetic trip occurs at 5–10× In (200–400 A), suited for motor or lighting circuits with moderate inrush.

Rated for overvoltage category III. Energy limiting class 3. Touch protection integrated. Halogen-free and silicon-free construction. Storage temperature range -40 to +75 °C. Ambient operating range -25 to +45 °C.

Frequently asked questions

How do I get current pricing and availability for 5SU9104-1KK40?

Submit an RFQ through this listing. The part is sourced to order through independent distribution; pricing and stock status are confirmed at quote time.

What is the closest functional second-source to 5SU9104-1KK40?

The 5SY7140-8CC is a comparable Siemens RCBO in the same SENTRON family, also 40 A, 10 kA, C-curve, 1P+N, Type AC, and 18 mm wide. The key difference is the 5SU9 series (5SU9104-1KK40) is an instantaneous RCD type, while the 5SY7 series may have different internal RCD characteristics — verify the specific RCD type (AC vs A vs F) and any time-delay requirements before substituting.

Will 5SU9104-1KK40 drop into a panel specified around 5SY7140-8CC without rewiring?

Form, fit, and function are identical — both are 18 mm wide, 1P+N, 40 A, C-curve, 10 kA RCBOs on DIN rail. No rewiring is needed for the mechanical fit or terminal connections (0.75–35 mm² solid/stranded). However, confirm the RCD type (AC vs A vs F) and any time-delay specification in the original design before swapping.

What compliance documentation does Siemens provide for 5SU9104-1KK40?

The device is designed to EN 60898 and IEC 60947-2. It is halogen-free and silicon-free. Standard Siemens documentation includes a CE declaration of conformity and RoHS/REACH compliance statements available on request.