Siemens 5SU9156-7KK06 — Residual Current Breakers (RCCB/RCBO)

Siemens 5SU9156-7KK06 SENTRON RCBO, 6A C-Char, 10mA, 1P+N

MPN5SU9156-7KK06

Siemens SENTRON 5SU9156-7KK06 RCBO, 6 kA (EN 60898) / 10 kA (IEC 60947-2), 6 A rated, C-curve, 10 mA type A, 1P+N, 2 MW, 230/240 V AC.

Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & sourcing agent· Listing updated Sep 2026

Specifications

5SU9156-7KK06 — Electrical Ratings
ParameterValue
Number of poles2
Overvoltage categoryIII
5SU9156-7KK06 — Identification
ParameterValue
Product designationRCD-operated circuit breaker
Product design / constructionInstantaneous
5SU9156-7KK06 — Mechanical
ParameterValue
Mounting positionany
Width in modular units2
Maximum75 °C
Minimum-40 °C
Width36 mm
Height90 mm
Depth77 mm
Installation depth70 mm
5SU9156-7KK06 — Environmental
ParameterValue
IP degree of protectionIP20, if the distribution board is installed, with connected conductors
5SU9156-7KK06 — Electrical
ParameterValue
Tripping Characteristic ClassC

Product details

It protects a single-phase final subcircuit against both overload/short-circuit and earth leakage. The 10 mA type A residual-current element catches sinusoidal AC faults plus pulsating DC faults up to 10 mA — the sensitivity level used for personal protection in wet or medical locations.

The higher IEC 60947-2 rating applies when the same RCBO is specified into an industrial panel under the product standard for circuit breakers — that 10 kA figure gives headroom for installation closer to a transformer or in a higher-fault location. The 4 000 V surge voltage resistance (impulse withstand) supports Overvoltage Category III installations, typical for fixed-wiring distribution boards downstream of the utility meter.

Supply can enter from either top or bottom — no orientation restriction. The IP20 rating applies once the distribution board is installed and conductors are connected; the enclosure itself provides the required touch protection.

Frequently asked questions

Will 5SU9156-7KK06 drop into a panel built for 5SL6550-7BB?

No — the 5SL6550-7BB is a miniature circuit breaker (MCB) without residual-current protection, while the 5SU9156-7KK06 is an RCBO. Both share the same 2-MW DIN footprint (36 mm wide), so the physical slot fits, but the wiring and circuit protection function are different.