Skip to main content
Siemens 5SU9156-7KK10 — Residual Current Breakers (RCCB/RCBO)

Siemens 5SU9156-7KK10 SENTRON RCBO, 2-pole, 10 A, 10 mA, Typ

MPN5SU9156-7KK10

Siemens SENTRON RCBO, 2-pole, 10 A rated, 10 mA Type A residual current, C-curve, 6 kA / 10 kA breaking capacity, instantaneous design, 36 mm wide (2 MW), depth 77 mm.

Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & sourcing agent· Listing updated Sep 2026

Specifications

5SU9156-7KK10 — Electrical Ratings
ParameterValue
Number of poles2
Overvoltage categoryIII
5SU9156-7KK10 — Identification
ParameterValue
Product designationRCD-operated circuit breaker
Product design / constructionInstantaneous
5SU9156-7KK10 — Mechanical
ParameterValue
Mounting positionany
Width in modular units2
Maximum75 °C
Minimum-40 °C
Width36 mm
Height90 mm
Depth77 mm
Installation depth70 mm
5SU9156-7KK10 — Environmental
ParameterValue
IP degree of protectionIP20, if the distribution board is installed, with connected conductors
5SU9156-7KK10 — Electrical
ParameterValue
Tripping Characteristic ClassC

Product details

The Siemens 5SU9156-7KK10 is a SENTRON RCD-operated circuit breaker — an RCBO that combines overcurrent protection and residual current detection in a single 2-module-wide (36 mm) package. The instantaneous design (no intentional time delay on the RCD element) means it trips on the first half-cycle of a residual fault — no selectivity with downstream delayed RCDs, but full speed for personnel protection.

Current derating and mounting

Rated 10 A at 30 °C ambient; derate to 9.4 A at 40 °C, 9.1 A at 45 °C, 8.7 A at 50 °C, and 8.1 A at 55 °C.

Frequently asked questions

What is the depth of 5SU9156-7KK10?

The depth is 77 mm, with an installation depth of 70 mm. The width is 36 mm (2 modular width units), height 90 mm.

Will 5SU9156-7KK10 drop into a panel specified for 5SY7210-7CC?

Both are 2-module-wide (36 mm) SENTRON RCBOs, so the physical footprint and DIN-rail clip are identical. However, the 5SU9156-7KK10 is a 10 A, 10 mA Type A instantaneous device, while the 5SY7210-7CC has different ratings — confirm the trip curve, residual type, and breaking capacity match your panel design before swapping.

Where can I buy 5SU9156-7KK10?

This part is sourced and quoted to order through independent distribution channels. Submit an RFQ for current availability and pricing — stock levels and lead time are confirmed at quote time.

MPN
5SU9156-7KK10