Siemens 5SU9156-7KK25 — Residual Current Breakers (RCCB/RCBO)

Siemens 5SU9156-7KK25 SENTRON RCD Circuit Breaker, 25 A, Typ

MPN5SU9156-7KK25

Siemens SENTRON 5SU9 series, RCD-operated circuit breaker, 1P+N, 25 A, Type A, C characteristic, 6 kA (EN 60898) / 10 kA (IEC 60947-2), 2 width units.

Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & sourcing agent· Listing updated Sep 2026

Specifications

5SU9156-7KK25 — Electrical Ratings
ParameterValue
Number of poles2
Overvoltage categoryIII
5SU9156-7KK25 — Identification
ParameterValue
Product designationRCD-operated circuit breaker
Product design / constructionInstantaneous
5SU9156-7KK25 — Mechanical
ParameterValue
Mounting positionany
Maximum1.5 W
Width36 mm
Height90 mm
Depth77 mm
Installation depth70 mm
5SU9156-7KK25 — Environmental
ParameterValue
IP degree of protectionIP20, if the distribution board is installed, with connected conductors
5SU9156-7KK25 — Electrical
ParameterValue
Tripping Characteristic ClassC

Product details

The Siemens 5SU9156-7KK25 is a SENTRON RCD-operated circuit breaker — an RCBO combining overcurrent protection and residual current detection in a single 36 mm wide (2 width units) package. The Type A fault-current detection catches pulsating DC residual currents, which standard AC-only RCDs miss — relevant for circuits feeding electronics, VFDs, or switching power supplies. The higher IEC rating applies when the device is used as a distribution circuit breaker per that standard; the EN rating governs domestic or similar installations. Overvoltage category III means it's rated for fixed-installation downstream of the utility meter, not for socket-outlet or equipment-level protection.

Thermal derating and conductor sizing

At 40 °C it derates to 23.5 A; at 45 °C to 22.75 A; at 50 °C to 21.75 A; at 55 °C to 20.25 A. If the panel internal ambient runs above 30 °C — common in a crowded enclosure — the load current must be reduced accordingly. The operating ambient range is -25 to +45 °C, so the 45 °C derating figure is the maximum continuous current at the top of the rated ambient band. That covers everything from a 1.5 mm² lighting circuit up to a 10 mm² feeder. The installation depth is 70 mm, with an overall depth of 77 mm including the front projection.

Frequently asked questions

How do I get current pricing and availability for 5SU9156-7KK25?

This part is sourced and quoted to order against an RFQ through independent distribution. Availability and current pricing are confirmed at quote time.

What is the difference between 5SU9156-7KK25 and 5SL6563-7BB?

The 5SL6563-7BB is a standard MCB without residual current protection. The 5SU9156-7KK25 is an RCBO combining overcurrent and Type A RCD protection in one unit. They are not drop-in replacements; the 5SU9156-7KK25 requires the neutral connection for the RCD function.

What compliance documentation does Siemens provide for 5SU9156-7KK25?

The device is designed per EN 60898 (6 kA) and IEC 60947-2 (10 kA). It carries overvoltage category III rating and touch protection. Specific RoHS, REACH, and UL documentation should be requested at quote time as the evidence does not list those certifications directly.

MPN
5SU9156-7KK25