Siemens 5SU9156-7KK32 — Residual Current Breakers (RCCB/RCBO)

Siemens 5SU9156-7KK32 SENTRON RCBO, 32 A, 10 mA, Type A, 2-p

MPN5SU9156-7KK32

Siemens SENTRON 5SU9156-7KK32, RCBO, 2-pole, 32 A, 10 mA, Type A, tripping characteristic C, 6 kA (EN 60898) / 10 kA (IEC 60947-2).

Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & sourcing agent· Listing updated Sep 2026

Specifications

5SU9156-7KK32 — Electrical Ratings
ParameterValue
Number of poles2
Overvoltage categoryIII
5SU9156-7KK32 — Identification
ParameterValue
Product designationRCD-operated circuit breaker
Product design / constructionInstantaneous
5SU9156-7KK32 — Mechanical
ParameterValue
Mounting positionany
Width in modular units2
Maximum75 °C
Minimum-40 °C
Width36 mm
Height90 mm
Depth77 mm
Installation depth70 mm
5SU9156-7KK32 — Environmental
ParameterValue
IP degree of protectionIP20, if the distribution board is installed, with connected conductors
5SU9156-7KK32 — Electrical
ParameterValue
Tripping Characteristic ClassC

Product details

The Siemens 5SU9156-7KK32 is a 2-pole RCBO — a combined residual-current device (RCD) and miniature circuit breaker (MCB) in one 36 mm wide module. Rated 32 A at 30 °C with a 10 mA residual-current trip threshold and Type A sensitivity, it catches sinusoidal AC faults and pulsating DC faults up to 10 mA.

Rated short-circuit capacity is 6 kA per EN 60898 and 10 kA per IEC 60947-2. The 10 kA figure under 60947-2 is the one that matters for industrial panel coordination — it tells you this RCBO can safely interrupt a fault up to 10 kA at the rated voltage without welding its contacts or cascading the arc upstream. The 6 kA EN 60898 rating is the residential/commercial standard; the higher IEC rating gives you headroom in a plant-floor distribution sub-panel.

Thermal derating and environment

At 40 °C it derates to 30.08 A; at 50 °C to 27.84 A; at 55 °C to 25.92 A.

Frequently asked questions

What is the breaking capacity of 5SU9156-7KK32?

6 kA per EN 60898 and 10 kA per IEC 60947-2. The 10 kA rating under 60947-2 is the figure to use for industrial panel coordination.

What is the residual current rating and type?

10 mA, Type A — it detects sinusoidal AC faults and pulsating DC faults up to that threshold.

Where can I buy 5SU9156-7KK32?

Sourced and quoted to order against an RFQ through independent distribution. Availability and current pricing are confirmed at quote time.

What is the difference between 5SU9156-7KK32 and 5SL6550-7BB?

The 5SL6550-7BB is a different class — a 2-pole MCB only, no residual-current protection. The 5SU9156-7KK32 is an RCBO (MCB + RCD combined). They share the same 36 mm width and DIN-rail footprint, but the 5SL6550-7BB cannot provide ground-fault protection. If your panel was wired around the 5SL6550-7BB, dropping in the 5SU9156-7KK32 requires checking that the neutral bar and wiring accommodate the additional RCD connections.