Skip to main content
Siemens 5SU9156-7VK06 — Residual Current Breakers (RCCB/RCBO)

Siemens 5SU9156-7VK06 SENTRON RCBO, 6 A, Type A, 30 mA, 10 k

MPN5SU9156-7VK06

Siemens SENTRON 5SU9156-7VK06 RCBO, 1P+N, 6 A, Type A, 30 mA, tripping characteristic C, 10 kA (IEC 60947-2), 77 mm deep, solid/stranded 0.75–35 mm².

Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & sourcing agent· Listing updated Sep 2026

Specifications

5SU9156-7VK06 — Electrical Ratings
ParameterValue
Number of poles2
Overvoltage categoryIII
5SU9156-7VK06 — Identification
ParameterValue
Product designationRCD-operated circuit breaker
5SU9156-7VK06 — Mechanical
ParameterValue
Mounting positionany
Maximum1.5 W
Width36 mm
Height90 mm
Depth77 mm
Installation depth70 mm
5SU9156-7VK06 — Environmental
ParameterValue
IP degree of protectionIP20, if the distribution board is installed, with connected conductors
5SU9156-7VK06 — Electrical
ParameterValue
Tripping Characteristic ClassC

Product details

The Siemens 5SU9156-7VK06 is a SENTRON RCBO — a combined RCD and MCB in one 2-module-wide (36 mm) package, 1P+N, rated 6 A with Type A fault current sensitivity (30 mA typical for this class). Breaking capacity is 6 kA per EN 60898 and 10 kA per IEC 60947-2, so it clears line-to-neutral faults up to that level on a 230 VAC supply at 50 Hz.

Snaps onto DIN rail EN 60715. Depth is 77 mm, installation depth 70 mm — check your enclosure depth before committing. Mounting position any, so it works upright, sideways, or inverted in a crowded panel. Touch protection is built in (fingertip-safe terminals).

Thermal derating and environment

Rated 6 A at 30 °C ambient. Derate continuously: 5.64 A at 40 °C, 5.46 A at 45 °C, 5.22 A at 50 °C, 4.86 A at 55 °C. If your panel runs hot (e.g., 45 °C inside), plan for the lower figure. IP20 with distribution board installed and conductors connected.

Frequently asked questions

What is the depth of 5SU9156-7VK06?

77 mm overall depth; installation depth is 70 mm (the part that sits behind the DIN rail).

What wire sizes does 5SU9156-7VK06 accept?

Solid or stranded copper from 0.75 mm² up to 35 mm² — covers most branch-circuit conductors.

Where can I buy 5SU9156-7VK06?

Sourced through independent distribution channels. Availability and current pricing are confirmed at quote time against an RFQ — no stock count or lead-time figure published here.

MPN
5SU9156-7VK06