Siemens 5SU9304-0KK10 — Residual Current Breakers (RCCB/RCBO)

Siemens 5SU9304-0KK10 SENTRON RCBO, 10A B-curve, 30mA, 2-pol

MPN5SU9304-0KK10
Active

Siemens SENTRON 5SU9304-0KK10 RCBO, 2-pole, 10 A rated current, B-curve, 30 mA residual current, 10 kA breaking capacity, 18 mm wide, IP20.

Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & sourcing agent· Listing updated Sep 2026

Specifications

5SU9304-0KK10 — Electrical Ratings
ParameterValue
Number of poles2
Overvoltage categoryIII
5SU9304-0KK10 — Identification
ParameterValue
Product designationRCD-operated circuit breaker
Product design / constructionInstantaneous
5SU9304-0KK10 — Mechanical
ParameterValue
Mounting positionany
Width in modular units1
Maximum75 °C
Minimum-40 °C
Width18 mm
Height125 mm
Depth77 mm
Installation depth70 mm
5SU9304-0KK10 — Environmental
ParameterValue
IP degree of protectionIP20, if the distribution board is installed, with connected conductors
5SU9304-0KK10 — Electrical
ParameterValue
Tripping Characteristic ClassB

Product details

The Siemens 5SU9304-0KK10 is a 2-pole RCBO — a combined residual-current device and miniature circuit breaker in a single 18 mm-wide module. It belongs to the SENTRON series and is rated for 10 A at 50/60 Hz with a B-curve tripping characteristic, meaning it protects against overcurrents and short circuits while also detecting earth leakage currents down to 30 mA. The 10 kA breaking capacity per EN 60898 and IEC 60947-2 is sufficient for most residential and light commercial distribution boards, and the instantaneous design (no time delay) means it trips without intentional delay on residual faults.

Installation depth is 70 mm, with an overall depth of 77 mm including the housing. Touch protection is built in.

Thermal derating and ambient limits

At 40 °C it derates to 9.4 A, at 45 °C to 9.1 A, at 50 °C to 8.7 A, and at 55 °C to 8.1 A.

Frequently asked questions

What is the breaking capacity of 5SU9304-0KK10?

10 kA per both EN 60898 and IEC 60947-2, which covers standard distribution board fault levels.

What is the residual current rating?

30 mA, type AC — suitable for sinusoidal AC earth faults. No time delay (instantaneous).

Will 5SU9304-0KK10 drop into a panel specified around 5SU9304-1KK32 without rewiring?

Both are 2-pole SENTRON RCBOs on the same 18 mm DIN-rail footprint, so mechanical fit is identical. The 1KK32 variant carries a different current/curve rating; verify the load-side protection coordination before swapping.

Where can I buy 5SU9304-0KK10?

Sourced and quoted to order against an RFQ through independent distribution channels. Availability and current pricing are confirmed at quote time.