Siemens 5SU9304-1KK20 — Residual Current Breakers (RCCB/RCBO)

Siemens 5SU9304-1KK20 SENTRON RCBO, 1P+N, 20 A, C-curve, 10

MPN5SU9304-1KK20
Active

Siemens SENTRON RCBO, 1P+N, 20 A at 30 °C, C-curve, 10 kA breaking capacity per EN 60898, 1 MW width, 77 mm depth.

Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & sourcing agent· Listing updated Sep 2026

Specifications

5SU9304-1KK20 — Electrical Ratings
ParameterValue
Number of poles2
Overvoltage categoryIII
5SU9304-1KK20 — Identification
ParameterValue
Product designationRCD-operated circuit breaker
Product design / constructionInstantaneous
5SU9304-1KK20 — Mechanical
ParameterValue
Mounting positionany
Width in modular units1
Maximum75 °C
Minimum-40 °C
Width18 mm
Height125 mm
Depth77 mm
Installation depth70 mm
5SU9304-1KK20 — Environmental
ParameterValue
IP degree of protectionIP20, if the distribution board is installed, with connected conductors
5SU9304-1KK20 — Electrical
ParameterValue
Tripping Characteristic ClassC

Product details

The Siemens 5SU9304-1KK20 is a SENTRON RCBO — an RCD-operated circuit breaker combining overcurrent and residual-current protection in a single 1 MW (18 mm) module. Rated 20 A at 30 °C with a C tripping curve, it breaks 10 kA per EN 60898 and IEC 60947-2, covering most residential and light commercial final circuits. The 1P+N design protects the live conductor only; the neutral is switched but not protected.

The 20 A rating at 30 °C derates to 18.8 A at 40 °C and 16.2 A at 55 °C — if the distribution board sits in a hot attic or near a boiler, size the upstream MCB accordingly. The C-curve (magnetic trip at 5–10× In) suits motor and lighting loads with moderate inrush; for purely resistive circuits a B-curve would trip faster. The IP20 rating applies only when the distribution board is installed and conductors are connected — not for open-panel use.

The 1 MW width (18 mm) means it occupies one slot in a standard modular enclosure. The test button requires a minimum 115 V to function; verify the test circuit voltage before commissioning.

Frequently asked questions

What is the breaking capacity of 5SU9304-1KK20?

10 kA per both EN 60898 and IEC 60947-2 at 230/240 V AC.

Will 5SU9304-1KK20 drop into a panel designed for 5SY4116-7CV?

Both are 1 MW wide (18 mm) DIN-rail RCBOs, but the 5SY4116-7CV is a 16 A B-curve device. The 5SU9304-1KK20 is a 20 A C-curve — check the circuit rating and trip coordination before swapping.

Where can I buy 5SU9304-1KK20?

Sourced and quoted to order against an RFQ through independent distribution. Submit a request for current pricing and availability.