Skip to main content
Siemens 5SU9304-6KK32

SENTRON 5SU9304-6KK32 RCBO, 20 A, B char, 30 mA Type A, 10 k

MPN 5SU9304-6KK32
Active

SENTRON RCBO, 1P+N, B characteristic, 20 A, 30 mA Type A residual current, 10 kA breaking capacity, 230 V AC, 18 mm wide, instantaneous design.

Dispatch SLA24-48h Global Rush
Quality CheckOriginal Seal & Physical QC
IncotermsDAP / DDP Available
Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & stockist· Listing updated Sep 2026

Specifications

5SU9304-6KK32 specifications
ParameterValue
Poles2
Depth77 mm
Width18 mm
Height125 mm
Energy limitation class3

Product details

The SENTRON 5SU9304-6KK32 is an RCBO — a combined RCD and MCB in one 18 mm wide module. It protects a single-phase 230 V AC final circuit against overload, short-circuit (B-curve, 20 A rated), and earth leakage (30 mA, Type A). Type A means it catches pulsating DC residual currents as well as sinusoidal AC — the standard for circuits with electronic loads like washing machines, LED drivers, or small VFDs. The 1P+N construction switches the live pole and provides a solid neutral through the device — the neutral is not switched but is monitored for residual current. This is the typical European final-circuit RCBO layout. The instantaneous design trips without intentional time delay, so it's the first line of earth-fault protection on a subcircuit.

At 18 mm wide (one modular unit), this RCBO fits a standard DIN-rail enclosure. That 77 mm depth includes the 600 mm pigtail — a factory-attached neutral tail that saves wiring time in the panel. The supply can enter from the top or bottom, and the mounting position is unrestricted. IP20 protection is achieved once the board is installed and conductors are connected — normal for inside a distribution cabinet. The 4 kV surge voltage resistance means it handles transient overvoltages from the mains without damage. The 1 kA surge current (8/20 µs waveform) is the impulse withstand for lightning-induced surges — typical for residential and light commercial service entrances.

Temperature and environment

Rated for -40 °C to +75 °C ambient, with max 95% humidity. That covers unheated outdoor enclosures in cold climates and hot machine cabinets near the ceiling. The 20 A rating at 30 °C and at AC confirms the thermal performance is consistent across normal operating conditions — no derating curve to chase for most installations.

MPN
5SU9304-6KK32