Siemens 5SU9304-7KK25 — Residual Current Breakers (RCCB/RCBO)

Siemens 5SU9304-7KK25 SENTRON RCBO, 25A C-curve, 10kA, 1P+N

MPN5SU9304-7KK25
Active

Siemens SENTRON 5SU9 series, RCD-operated circuit breaker (RCBO), 25 A rated AC, C tripping characteristic, 10 kA breaking capacity, Type A, 1P+N, 18 mm width, 77 mm depth.

StockContact for availability
MOQ1 pcs
Sourced new & surplus through independent channelsListing updated Jul 2026

Specifications

Electrical Ratings

5SU9304-7KK25 — Electrical Ratings
ParameterValue
Number of poles2
Overvoltage categoryIII

Identification

5SU9304-7KK25 — Identification
ParameterValue
Product designationRCD-operated circuit breaker
Product design / constructionInstantaneous

Mechanical

5SU9304-7KK25 — Mechanical
ParameterValue
Mounting positionany
Maximum0.75 W
Width18 mm
Height125 mm
Depth77 mm
Installation depth70 mm

Environmental

5SU9304-7KK25 — Environmental
ParameterValue
IP degree of protectionIP20, if the distribution board is installed, with connected conductors

Electrical

5SU9304-7KK25 — Electrical
ParameterValue
Tripping Characteristic ClassC

Product details

What it is and what it does

The Siemens 5SU9304-7KK25 is a 1P+N RCD-operated circuit breaker (RCBO) from the SENTRON 5SU9 series, combining overcurrent protection and residual current detection in a single 18 mm wide module. It's rated 25 A at AC with a C tripping characteristic, meaning it handles moderate inrush from motor or lighting loads without nuisance trips. The Type A fault current detection covers sinusoidal AC and pulsating DC residual currents — the standard for most commercial and light industrial circuits. Breaking capacity is 10 kA per both EN 60898 and IEC 60947-2, so it safely clears faults up to that level without cascading upstream.

Thermal derating and conductor sizing

The 25 A rating holds at 30 °C ambient; at 40 °C it derates to 23.5 A, at 45 °C to 22.75 A, at 50 °C to 21.75 A, and at 55 °C to 20.25 A. If the panel runs warm — say near a transformer or drive — size the load accordingly. Terminals accept solid or stranded conductors from 0.75 mm² up to 35 mm², covering most branch-circuit wiring. Power dissipation is a modest 0.75 W at rated load, so heat buildup in a crowded enclosure is minimal.

Mounting and integration

Snaps onto standard DIN rail, occupies one width unit (18 mm), and the installation depth behind the panel is 70 mm (total depth 77 mm). Mounting position is unrestricted — horizontal, vertical, upside-down, it doesn't care. Supply can feed from top or bottom. IP20 with the distribution board installed and conductors connected; touch protection is built in. Overvoltage category III means it's rated for fixed-installation use downstream of the main distribution board.

Frequently asked questions

What is the breaking capacity of 5SU9304-7KK25?

10 kA per EN 60898 and also 10 kA per IEC 60947-2, covering both the MCB and RCBO standards.

What conductor sizes does 5SU9304-7KK25 accept?

Solid or stranded conductors from 0.75 mm² up to 35 mm².

Where can I buy 5SU9304-7KK25 and how is it quoted?

Sourced and quoted to order against an RFQ through independent distribution channels. Availability and current pricing are confirmed at quote time.