Siemens 5SU9304-7KX16 — Residual Current Breakers (RCCB/RCBO)

Siemens 5SU9304-7KX16 SENTRON RCBO, 2-pole, 16 A, 30 mA, C-c

MPN5SU9304-7KX16
Active

Siemens SENTRON 5SU9304-7KX16, RCBO, 2-pole, 16 A rated, 30 mA Type A residual current, C-curve, 10 kA breaking capacity per EN 60898, 1 MW DIN-rail width.

StockContact for availability
MOQ1 pcs
Sourced new & surplus through independent channelsListing updated Jul 2026

Specifications

Electrical Ratings

5SU9304-7KX16 — Electrical Ratings
ParameterValue
Number of poles2
Overvoltage categoryIII

Identification

5SU9304-7KX16 — Identification
ParameterValue
Product designationRCD-operated circuit breaker
Product design / constructionInstantaneous

Mechanical

5SU9304-7KX16 — Mechanical
ParameterValue
Mounting positionany
Width in modular units1
Maximum75 °C
Minimum-40 °C
Width18 mm
Height125 mm
Depth77 mm
Installation depth70 mm

Environmental

5SU9304-7KX16 — Environmental
ParameterValue
IP degree of protectionIP20, if the distribution board is installed, with connected conductors, IP40 is achieved

Electrical

5SU9304-7KX16 — Electrical
ParameterValue
Tripping Characteristic ClassC

Product details

The Siemens 5SU9304-7KX16 is a 2-pole RCBO from the SENTRON series — an RCD-operated circuit breaker combining overcurrent and residual current protection in one 18 mm-wide module. It's rated 16 A at 30 °C with a 30 mA Type A residual trip, C-curve magnetic release, and 10 kA breaking capacity per EN 60898 (also rated 10 kA per IEC 60947-2). That 30 mA Type A trip catches pulsating DC fault currents from electronics and single-phase rectifiers — common in modern loads like switched-mode supplies and LED drivers. The C-curve (5-10x In) handles motor inrush and capacitive loads without nuisance trips, while the 10 kA SCCR at 230/400 V means it clears a hard fault without upstream breaker coordination issues in a residential or light commercial panel.

Snaps onto standard DIN rail, one modular width (18 mm). Depth is 77 mm, installation depth 70 mm — fits flush in a 125 mm-tall enclosure with the gland plate clear. Mounting position any, so it works in vertical or horizontal busbar configurations. IP20 bare; once the distribution board is installed with connected conductors it achieves IP40 — fine for enclosed panels, not for washdown zones. Supply feeds from below per the position-of-power-supply-cord spec.

Derating matters here: at 30 °C it carries the full 16 A; at 40 °C it's 15.2 A; at 45 °C it drops to 14.56 A; at 50 °C it's 14.08 A; at 55 °C it's 13.76 A. If your panel ambient runs hot near the top of the enclosure, factor that curve into the load schedule — don't load a 40 °C row at 16 A. Halogen-free and silicon-free construction, overvoltage category III, pollution degree 2. Touch protection is built in. Energy limitation class 3 — fast arc quenching limits let-through energy, which helps with downstream coordination on a 10 kA fault.

Frequently asked questions

How do I get current pricing and availability for 5SU9304-7KX16?

Submit an RFQ through this listing. The part is sourced to order via independent distribution; availability and current pricing are confirmed at quote time.

What is the difference between 5SU9304-7KX16 and 5SL3116-6MB?

The 5SL3116-6MB is a standard MCB (overcurrent only), while the 5SU9304-7KX16 is an RCBO that adds 30 mA Type A residual current protection in the same 18 mm footprint. If your circuit requires GFCI-level ground-fault protection, the 5SU9304-7KX16 replaces both an MCB and a separate RCD in one DIN slot. Panel wiring is the same — both are 2-pole, 16 A, C-curve, 10 kA, 1 MW wide — but the RCBO needs the neutral conductor routed through the device for the residual-current sense coil.

Will 5SU9304-7KX16 drop into a panel specified around 5SL3116-6MB without rewiring?

Physically yes — same 18 mm width, same DIN-rail mount, same 2-pole form factor. But the RCBO requires the neutral conductor to pass through the device for residual current sensing, whereas a standard MCB only breaks the line. If the existing panel feeds neutral past the MCB on a separate bus, you'll need to reroute it through the RCBO's neutral terminal.