Specifications

5SU9304-7KX32 — Electrical Ratings
ParameterValue
Number of poles2
Overvoltage categoryIII
5SU9304-7KX32 — Identification
ParameterValue
Product designationRCD-operated circuit breaker
Product design / constructionInstantaneous
5SU9304-7KX32 — Mechanical
ParameterValue
Mounting positionany
Maximum5.21 W
Width18 mm
Height125 mm
Depth77 mm
Installation depth70 mm
5SU9304-7KX32 — Environmental
ParameterValue
IP degree of protectionIP20, if the distribution board is installed, with connected conductors, IP40 is achieved
5SU9304-7KX32 — Electrical
ParameterValue
Tripping Characteristic ClassC

Product details

RCD-operated circuit breaker — 32 A, Type A, C-curve

The Siemens 5SU9304-7KX32 is a SENTRON RCBO — an RCD-operated circuit breaker combining overcurrent and residual current protection in a single 18 mm wide module. The Type A fault-current detection catches pulsating DC residual currents from rectified loads (VFDs, switched-mode supplies) that a plain AC type would miss. Breaking capacity is 10 kA per EN 60898 and IEC 60947-2, so it safely interrupts fault currents up to that level in a 230/400 V distribution board.

Thermal derating and installation

Rated current holds at 32 A up to 30 °C ambient; above that it derates stepwise — 30.4 A at 40 °C, 29.12 A at 45 °C, 28.16 A at 50 °C, 27.52 A at 55 °C. The operating ambient range is -25 to +45 °C, storage -40 to +75 °C. Mounting position is any, installation depth 70 mm, overall depth 77 mm. Protection class is IP20 with the distribution board installed; with connected conductors it achieves IP40.

Frequently asked questions

What is the breaking capacity of 5SU9304-7KX32?

10 kA per EN 60898 and IEC 60947-2, which covers most residential and light commercial distribution board fault levels.

What conductor sizes does 5SU9304-7KX32 accept?

Solid or stranded conductors from 0.75 mm² up to 35 mm², covering final circuit wiring from lighting to heavy appliance feeds.

Where can I buy 5SU9304-7KX32?

Sourced and quoted to order against an RFQ through independent distribution; availability and current pricing are confirmed at quote time.