Skip to main content
Siemens 5SU9306-0KK32 — Residual Current Breakers (RCCB/RCBO)

Siemens 5SU9306-0KK32 SENTRON RCBO, 32 A, 30 mA, B Curve, 6

MPN5SU9306-0KK32
Active

Siemens SENTRON RCBO, 5SU9306-0KK32, 2-pole 1P+N, 32 A rated, 30 mA AC-type residual current, B curve, 6 kA breaking capacity per EN 60898, 1 MW width.

Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & sourcing agent· Listing updated Sep 2026

Specifications

5SU9306-0KK32 — Electrical Ratings
ParameterValue
Number of poles2
Overvoltage categoryIII
5SU9306-0KK32 — Identification
ParameterValue
Product designationRCD-operated circuit breaker
Product design / constructionInstantaneous
5SU9306-0KK32 — Mechanical
ParameterValue
Mounting positionany
Width in modular units1
Maximum75 °C
Minimum-40 °C
Width18 mm
Height125 mm
Depth77 mm
Installation depth70 mm
5SU9306-0KK32 — Environmental
ParameterValue
IP degree of protectionIP20, if the distribution board is installed, with connected conductors
5SU9306-0KK32 — Electrical
ParameterValue
Tripping Characteristic ClassB

Product details

What this RCBO carries in the carton

The Siemens 5SU9306-0KK32 is a 2-pole (1P+N) SENTRON RCBO — an RCD-operated circuit breaker that combines overcurrent protection and residual-current detection in a single 1-module-width (18 mm) package. Rated 32 A at AC with a 30 mA AC-type residual trip, B-curve tripping characteristic, and 6 kA breaking capacity per both EN 60898 and IEC 60947-2. The kit is complete: one unit, touch-protected terminals, supply feed from either top or bottom. No loose accessories to chase.

Temperature derating — the real current limit

At 40 °C the continuous current drops to 30.08 A; at 45 °C to 29.12 A; at 50 °C to 27.84 A; at 55 °C to 25.92 A.

One modular width (18 mm wide, 125 mm tall, 77 mm deep, 70 mm installation depth). Mounts in any orientation on standard DIN rail. IP20 with connected conductors and distribution board installed. Halogen-free and silicon-free construction. Energy limitation class 3.

Frequently asked questions

How do I get current pricing and availability for 5SU9306-0KK32?

Submit an RFQ. The part is sourced to order through independent distribution; availability and current pricing are confirmed at quote time.

What is the difference between 5SU9306-0KK32 and 5SL6132-6MB?

The 5SU9306-0KK32 is an RCBO (RCD + MCB in one unit) with a 30 mA residual-current trip. The 5SL6132-6MB is a standard MCB only — no residual-current protection. They are not drop-in substitutes; the 5SU9306-0KK32 replaces both a separate RCD and MCB in one 1-MW slot.

What compliance documentation does Siemens provide for 5SU9306-0KK32?

The part carries approvals per EN 60898 and IEC 60947-2, is halogen-free and silicon-free, and is classified per IEC 81346-2 and DIN EN 61346-2. Specific RoHS/REACH/UL declarations are available from Siemens documentation on request.

MPN
5SU9306-0KK32